Disassembly of Meter (Continued)

Removing Bearing Plate
1)
Remove the bearing plate retaining screws with a standard flathead screwdriver.
2)
To remove bearing plate & rotors, insert a screwdriver into the notches near the dowel pins.
3)
Gently pry the bearing plate off the dowel pins and slide out the bearing plate and rotors from the
housing.
1
Removing Lock Nuts & Rotors
4)
Remove rotor lock nuts from each gear.
5)
Pull gears off of rotor shaft.
6)
Remove rotor key using pliers (this might not be necessary as rotor may slide right out of bearing
plate).
7)
Remove rotors from bearing plate.