Disassembly of Meter

All internal pressure must be relieved to ZERO (0) pressure before beginning disassembly
of meter or components
Draining Meter & Removing Counter Support
1)
Drain the meter by turning it on either the inlet or outlet side.
2)
Remove the counter bracket screws with a hex wrench or socket driver.
3)
Remove the drain plugs on the front and rear covers using an allen wrench. Allow more fluid to
drain from the meter.
1
Removing Packing Capsule
1)
Remove the retaining plate using a standard flathead screwdriver.
2)
Pull out the packing gland from the meter.
1