Specifications

The specifications of the UPS models and the extended battery modules are shown
in the following tables.
Note: All dimensions include the front bezel.
Table 1. 6000 VA LCD 4U rack UPS specifications
Specification
Height
Width
Depth
Weight
Operating temperature at 0 to
maximum altitude
24 hour transport storage
temperature at 0 to maximum
storage altitude
Extended storage temperature at
0 to maximum storage altitude
Maximum operating altitude
Maximum storage altitude
Relative humidity
Nominal input voltage
Maximum input current
Input voltage range for main
operations (V ac)
Nominal output voltage (V ac)
Input frequency
Rated power output
Output power capacity in watts
Circuit breakers
Fixed power cord
Input connection type
Power outlets
Audible noise at 1 meter for >
80% load
Runtime (for fully charged
internal batteries at 25°C)
6000 VA LCD 4U rack UPS
(200 V / 208 V)
171.5 mm (6.8 in.)
483 mm (19 in.)
735 mm (28.9 in.)
72 kg (159 lb)
0°C to 40°C (32°F to 104°F)
-15°C to 60°C (5°F to 140°F)
-15°C to 45°C (5°F to 113°F)
3048 m (10,000 ft)
15,240 m (50,000 ft)
0 to 95% noncondensing
208 V (auto sensing at first power-up) 230 V (auto sensing at first power-up)
30 amps
155 to 255 V ac
208 V (auto sensing at first power-up;
user configurable)
50/60 Hz ± 3 Hz (auto sensing)
6000 VA
5600 W
Three two-pole output breakers: two
for Load Segment 1 rated at 20 A,
one for Load Segment 2 rated at 30 A
Hard-wired
Terminal block
Two NEMA L6-30R
Four IEC 320 - C19
<55 dBA normal / Bypass mode
<55 dBA Battery mode
Full load: 5 min
Half load: 14 min
6000 VA LCD 4U rack UPS
(230 V)
171.5 mm (6.8 in.)
483 mm (19 in.)
735 mm (28.9 in.)
72 kg (159 lb)
0°C to 40°C (32°F to 104°F)
-15°C to 60°C (5°F to 140°F)
-15°C to 45°C (5°F to 113°F)
3048 m (10,000 ft)
15,240 m (50,000 ft)
0 to 95% noncondensing
32 amps
160 to 286 V ac
230 V (auto sensing at first power-up;
user configurable)
50/60 Hz ± 3 Hz (auto sensing)
6000 VA
5600 W
Three single-pole output breakers: two
for Load Segment 1 rated at 20 A, one
for Load Segment 2 rated at 15 A
Hard-wired
Terminal block
Six IEC 320 - C13
Four IEC 320 - C19
<55 dBA normal / Bypass mode
<55 dBA Battery mode
Full load: 5 min
Half load: 14 min