IBM 6000VA LCD 4U Rack UPS
IBM System x at-a-glance guide
The IBM 6000VA LCD 4U Rack uninterruptible power supply (UPS) delivers 5600 watts of power in only
4U of rack space, providing smart energy management and the highest level of power protection that
today's IT infrastructures require. With an efficiency rating of 95% or greater, the UPS helps reduce
energy usage and cooling costs, improves energy management, and optimizes workload performance
and availability for IBM System x and BladeCenter server applications. This high-density UPS packs
more real power (watts) into a space-saving 4U of rack space to protect more equipment and leaves room
for expanding IT systems. The IBM 6000VA LCD 4U Rack UPS is shown in Figure 1.
Figure 1. IBM 6000VA LCD 4U Rack UPS for IBM System x
Did You Know?
The IBM 6000VA UPS has a bright, easily customizable, and graphical LCD display that lets you
configure the device and displays important UPS status information in one of nine languages (English,
French, German, Spanish, Russian, Korean, Japanese, Simplified Chinese, and Traditional Chinese).
The UPS is exceptionally easy to manage and an ideal solution for standardization across the global
enterprise.
This UPS enhances system availability with Advanced Battery Management (ABM) technology. This
technology significantly extends battery service life; allows individual control of receptacle groups to
maximize run time for critical devices in the event of a prolonged power outage; provides a real-time clock
that enables precise shutdown and power up of systems in a preferred sequence; and records specific
power-related occurrences for more accurate trending and data analyses.
The IBM 6000VA UPS integrates with IBM Systems Director Active Energy Manager to help improve
energy management.
IBM 6000VA LCD 4U Rack UPS
1

Advertisement

Table of Contents
loading

Summary of Contents for IBM 6000VA

  • Page 1 IBM 6000VA LCD 4U Rack UPS IBM System x at-a-glance guide The IBM 6000VA LCD 4U Rack uninterruptible power supply (UPS) delivers 5600 watts of power in only 4U of rack space, providing smart energy management and the highest level of power protection that today's IT infrastructures require.
  • Page 2: Part Number Information

    Selecting the right IBM UPS can help protect against these potentially costly incidents. Part number information Table 1 lists the orderable part numbers and feature codes for the IBM 6000VA UPS. Table 1. Ordering part numbers and feature codes Description...
  • Page 3 Features The IBM 6000VA LCD 4U Rack UPS has the following features and capabilities: Occupies only 4U of vertical rack space.  Has over 95% energy efficiency at 100% load.  Offers six or 10 output receptacles:  Model 5395-6AX (200V/208V) has two NEMA L6-30R and four IEC 320 C19 receptacles.
  • Page 4: Specifications

    Specifications Table 2 lists the specifications for the three 6000VA UPS models. Table 2. Specifications (Part 1 of 2) Specification IBM 6000VA LCD 4U Rack UPS IBM 6000VA LCD 4U Rack UPS (200V/208V) (230V) IBM part number 5395-6AX 5395-6KX VA/Watts rating...
  • Page 5: Physical Specifications

    Battery run times and recharge times Table 3 lists the expected period that the 6000VA UPS will operate solely on batteries. The run times for the 230V model are the same as the 200/208V model. Table 3. IBM 6000VA UPS runtime chart...
  • Page 6: Front Panel Controls

    Supported rack installation The IBM 6000VA LCD 4U Rack UPS requires 4U of rack space in one of the following rack cabinets: IBM 42U Enterprise rack  IBM S2 42U Dynamic rack  IBM S2 42U rack  IBM S2 25 U rack ...
  • Page 7 On the Meter and Notice/Alarm screens, to lock the screen (prevent the screen from returning to its  default after timeout). A locked screen displays a small key image near the status icon. To unlock the screen, press any button to perform its usual function. IBM 6000VA LCD 4U Rack UPS...
  • Page 8: Rear Panel

    Rear panel Figure 3 shows the rear panel of the IBM 6000VA LCD 4U Rack UPS (200V/208V). Figure 3. Rear panel of the IBM 6000VA LCD 4U Rack UPS (200V/208V) Figure 4 shows the rear panel of the IBM 6000VA LCD 4U Rack UPS (230V).
  • Page 9 The 6000VA LCD 4U Rack UPS is designed to work with power distribution units (PDUs) such as the new IBM 0U 24 C13 30A PDU, which mounts vertically in a rack pocket and does not consume any of the rack units used for servers and storage.
  • Page 10: Network Management Card

    For applications requiring extended backup times, an external battery module can also be added to the 6000VA models to deliver hours of run time to critical systems during a prolonged power outage. The IBM 3U Extended Battery Module (EBM) is a 3U rack-mounted device that contains additional batteries.
  • Page 11 The IBM LCD UPS Network Management Card: Allows simultaneous shutdown of protected servers  Allows configuration of automatic email messages in response to UPS alarms and to transmit periodic  reports (see Figure 8) Allows control of UPS on/off switching with a web browser ...
  • Page 12 UPS shutdown occurs. Figure 9 shows normal operating using the IBM UPS Manager. The input voltage is 122V, which is within the acceptable range, and is shown in the left pane. The output voltage of the UPS is 121V and is also within the acceptable range.
  • Page 13 Figure 9. IBM UPS Manager normal status window IBM 6000VA LCD 4U Rack UPS...
  • Page 14 Figure 10 shows that the utility power supply has failed and that the UPS is now operating on battery. The UPS Manager software indicates that there is 10 minutes of battery time available based on the current load. Figure 10. IBM UPS Manager warning status window IBM 6000VA LCD 4U Rack UPS...
  • Page 15 Figure 11 shows the event notification window where you can configure how you (and other users) want to be notified when certain events occur. Figure 11. Event Notification window IBM 6000VA LCD 4U Rack UPS...
  • Page 16 Its temperature and humidity thresholds are easily set to trigger alarm notifications or shut down the  protected system. Its status can be monitored from the IBM Systems Director AEM or from the Network Management  Card web interface. It measures temperatures between 0 and 80°C (32 and 176°F) with an accuracy of ±1°C.
  • Page 17 AEM collects power information for each device attached to an IBM UPS, presenting a more complete view of energy usage within the data center. The IBM Systems Director Active Energy Manager (AEM) helps: Collect power information from each device attached to an IBM UPS, thus presenting a more ...
  • Page 18: Related Publications

    IBM US Product Announcement  http://ibm.com/common/ssi/cgi-bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS110-159 IBM System x UPS product page  http://www.ibm.com/systems/x/hardware/options/upsrack.html IBM 6000VA LCD 4U Rack Uninterruptible Power Supply Installation and Maintenance Guide  http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5085548 Network Management Card User Guide  http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5085199 IBM System x Configuration and Options Guide ...
  • Page 19 Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk.IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
  • Page 20 Machines Corporation in the United States, other countries, or both. These and other IBM trademarked terms are US registered or common law trademarks owned by IBM at the time this information was published. Such trademarks may also be registered or common law trademarks in other countries. A current list of IBM trademarks is available on the Web at http://www.ibm.com/legal/copytrade.shtml...

This manual is also suitable for:

5395-6ax5395-6kx

Table of Contents