Facing Material - Outdoor Lifestyles Twilight-II-C Installation Manual

Installation and appliance setup
Hide thumbs Also See for Twilight-II-C:
Table of Contents

Advertisement

C. Facing Material
Inside Facing Material
• May install combustible materials up to specified
clearances on top, front and sides of appliance.
• Seal joints between fi nished wall and appliance top and
sides with 300 ºF (140 ºC) minimum sealant.
• Leave space so bottom grille can be lowered for trim
door removal.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
NON-COMBUSTIBLE ZONE
41-7/8 in.
Figure 8.8 Non-combustible Zone (Interior)
Finishing Material Clearances
OVERHANG
FINISHING MATERIALS
A
SIDING
MINIMUM CLEARANCES
Vinyl
A
36 in.
B
64-5/16 in.
Figure 8.9 Exterior View - Finishing Material Clearances
26
Outdoor Lifestyles by Hearth & Home Technologies • Twilight-II-C Installation Manual • 2368-970 Rev. C • 2/15
8-5/16 in.
B
A
SIDING
A
SIDING
Non-vinyl
12 in.
35-5/16 in.
WARNING
Risk of Fire
• Non-combustible clearances must be
maintained.
• Sheetrock, wood or other combustibles must NOT
be used as sheathing or facing in the non-
combustible zone.
• See Sections 3 & 8 for proper clearances.
• See Section 1 for combustible/non-
combustible defi nitions.
May install non-combustible materials to cover gap be-
tween facing material and appliance (see Figure 8.10).
WARNING
Fire Risk.
Water Intrusion Risk.
Hood is required.
• Flashing and non-combustible sheathing must be
installed before facing materials.
• Facing must be non-combustible and seal tight to
fi replace front.
WARNING
Fire Risk.
Finish all edges and fronts to clearances
and specifi cations listed in manual.
• Black metal columns may be covered with
non-combustible material only.
• Do NOT overlap combustible materials onto appliance
front.
• Install combustible materials only up to specified
clearances on top, front and side edges.
• Seal joints between the fi nished wall and appliance top
and sides using only a 300 ºF minimum sealant.
NOTICE: If using an acid-based wash to clean fi nishing
material, cover the face of the fi replace with plastic sheet
to protect the paint. Remove plastic before operation of
fi replace.

Hide quick links:

Advertisement

Table of Contents
loading