B. Facing Material
WARNING
Fire Risk
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
• Modifying or covering grilles could cause
temperature rise and fire hazard.
Finishing materials must not interfere with:
•
Air flow through grilles or louvers.
• Operation of louvers or doors.
• Access for service.
Finish wall material
may be combustible,
top & sides.
0 in.
Sealant Material
Figure 8.2
Noncombustible Facing Diagram
WARNING
Fire Risk
Finish all edges and fronts to clearances and
specifications listed in manual.
• Metal appliance front may be covered with non-
combustible material only.
• Do NOT overlap combustible materials onto appliance
front.
•
Install combustible materials up to specified clearances
on top front and side edges.
•
Seal joints between the finished wall and appliance
top and sides using only a 300° F minimum sealant.
16
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev L 10/09
Upper front can be covered
with non-combustible
material or removed and
replaced with non-
combustible material.
0 in.
0 in.