HOUSEWRAP (BUILDING
PAPER) AND SHEATHING
SEE FIGURE 10.5
Figure 8.12 Exterior View with Non-combustible Facing Material
28
Outdoor Lifestyles by Hearth & Home Technologies • Twilight-II-C Installation Manual • 2368-970 Rev. C • 2/15
SIDING
DETAIL -
INSULATION
APPLIANCE
HOOD
SOFFIT
DRAIN PLANE
DETERMINED BY
MINIMUM CLEARANCE
LOCAL CODE
CLEARANCE TO VINYL
SOFFIT, OVERHANG, MANTEL,
12 in.
MINIMUM CLEARANCE
TO NON-VINYL SIDING
36 in. MINIMUM
CLEARANCE TO VINYL SIDING
TOP OF
APPLIANCE
BRICK OR OTHER NON-COMBUSTIBLE
FACING MATERIAL 6 INCH MAXIMUM
PROJECTION FROM SURFACE OF
FIREPLACE (INCLUDES NON-COMBUSTIBLE
MANTEL PROJECTION)
NON-COMBUSTIBLE BRICK LEDGE
MUST BE TIGHT TO APPLIANCE
FACE OR NON-COMBUSTIBLE SHEATHING
35-5/16 in.
TO NON-VINYL
64-5/16 in.
OR CEILING
TOP OF HOOD