INSTALLATION
WINDOW INSTALLATON
Installing the Window Filler Panels
INSTALLATION
1. Measure distance "X" between the face of the window stop
THRU-WALL INSTALLATION
molding and the side of the cabinet (Fig. 11).
Note: Measure both sides of unit separately.
INSTALLATION
2. Subtract one groove (3/16") from "X" measurement to obtain the
required width. Using a sharp knife, score the groove until the
filler panel becomes weak enough to break apart (Fig. 12).
3. Insert cut edge of the filler panel into the cabinet side seal groove
(position 1). Leave a small space at the bottom of the cabinet side
seal groove (Fig. 13).
OPERATION
Rotate the filler panel backward toward the window frame until
ELECTRONIC CONTROLS
the filler panel clears the window sill. Push the filler panel down
against the window sill (position 2).
Slide the filler panel out from the air conditioner cabinet until the
MAINTENANCE
filler panel flange contacts the window stop molding (position 3)
AIRFLOW / FILTER
(Fig. 14).
4. Attach the filler panel to the face of the window stop molding by
driving upholsterers' tacks through the holes in the filler panel
flange (Fig. 15).
11
11
B
A
13
G
15
F
C
H
E
C
G
L
K
5. Pull the sliders out until the sliders contact the face of the window
stop molding (Fig.16).
6. Pull bottom window sash down tightly and lock it in place by
installing a 5/8" long screw through the hole in the slider into the
window sash (Fig. 16).
7. Cut the plastic foam seal to proper length and insert it between
the upper and the lower window sash.
Installing the Chassis into the Cabinet
1. Slide the chassis into the cabinet.
2. To replace the front, place the top of the decorative front in
position and pivot back towards the unit and snap into place.
Replace screws and air filter.
3. Replace the two (2) antitheft screws at the bottom side of cabinet.
4. Use sealant to fill any minor openings.
5. Make sure unit is OFF, before plugging into the outlet.
Use caution when working around exposed sharp edges of the
cabinet and sharp coils to avoid injury or torn clothing.
12
C
D
14
G
C
J
I
16
O
N
4
Face of window stop
A
molding
Side of cabinet
B
Filler Panel
C
"X" minus one
D
groove (3/16")
Cabinet side seal
E
Cabinet
F
Window stop
G
molding
Position 1
H
F
Position 2
I
Position 3
J
Holes in flange
K
Upholsterers' tacks
L
Hole in slider
M
E
Slider
N
1" long screw
O
M