Epson Stylus NX100 Service Manual page 97

Hide thumbs Also See for Stylus NX100:
Table of Contents

Advertisement

Epson Stylus NX100/105/SX100/105/TX100/101/102/103/105/106/109/ME 300/ME OFFICE 360/NX110/115/SX110/115/TX110/111/112/113/115/117/119
Install the FFC according to the following procedures.
1.
Lead the FFC through the hole of the Holder FFC and
Main Frame.
Holder FFC
Figure 4-85. Installing the CR Unit (3)
2.
Secure the FFC with rib A and rib B.
Figure 4-86. Installing the CR Unit (4)
DISASSEMBLY/ASSEMBLY
FFC
Hole
Rib B
Rib A
Disassembling the Printer Mechanism
3.
Fold back the FFC and secure it with rib A again.
Figure 4-87. Installing the CR Unit (5)
4.
Fold back only the Head FFC and secure it with rib A again.
5.
Connect the FFC to the Main Board (J8, J9).
Head FFC
Figure 4-88. Installing the CR Unit (6)
Whenever the CR Unit is removed/replaced, the required
A D J U S T M E N T
R E Q U I R E D
adjustments must be carried out.
Chapter 5 " ADJUSTMENT" (p.110)
Revision C
Rib A
FFC
Rib A
Confidential
FFC
97

Hide quick links:

Advertisement

Table of Contents
loading