Epson Stylus NX100/105/SX100/105/TX100/101/102/103/105/106/109/ME 300/ME OFFICE 360/NX110/115/SX110/115/TX110/111/112/113/115/117/119
When routing the Ink Tube, confirm the following.
Insert point A of the tube carefully into the Cap Assy not to let
it pressed. (See Fig.4-53, Fig.4-64)
Align point D with the right edge of the hook on the ASF Unit,
then secure it. (See Fig.4-54, Fig.4-64)
Insert the Holder Tube up to point E as shown below, and insert
the holder into the Duct Tube End. (See Fig.4-54, Fig.4-64)
Figure 4-56. Installing the Pump Assy (1)
Route the Waste Ink Tube through the ribs of the Lower
Housing as shown below.
Figure 4-57. Installing the Pump Assy (2)
Whenever the Ink System removed/replaced, the required
A D J U S T M E N T
R E Q U I R E D
adjustments must be carried out.
Chapter 5 " ADJUSTMENT" (p.110)
DISASSEMBLY/ASSEMBLY
Point E
Holder Tube
Ink Tube
Ink Tube
Disassembling the Printer Mechanism
DISASSEMBLING THE CAP ASSY
Disassembly Procedure
Do not contaminate or damage the Sealing Rubber, Blade Wiper,
C A U T I O N
and Felt Wiper.
1.
Remove the Foam Cap Side from the Case Cleaner.
2.
Release the two hooks of the IS Cap Assy, and remove the Blade Wiper and
Felt Wiper.
Case Cleaner
Rib
Figure 4-58. Disassembling the Cap Assy (1)
Revision C
Foam Cap Side
Blade Wiper
Felt Wiper
IS Cap Assy
Hook