Hide thumbs Also See for Stylus NX100:
Table of Contents

Advertisement

Epson Stylus NX100/105/SX100/105/TX100/101/102/103/105/106/109/ME 300/ME OFFICE 360/NX110/115/SX110/115/TX110/111/112/113/115/117/119

4.5.3 Hopper

Parts/Components need to be removed in advance:
Scanner Stand/Cover Wire
(p
68), Scanner Unit
Panel Unit
(p
72)
Removal procedure
1.
Release both the dowels that secure the Hopper, and remove the Hopper and
the Compression Spring from the Lower Housing.
Lower Housing
Compression Spring
Figure 4-38. Removing the Hopper
DISASSEMBLY/ASSEMBLY
(p
70), Middle Housing
(p
71)
Hopper
Hook
Disassembling the Printer Mechanism
2.
Release the hook that secures the Edge Guide, and remove the Hopper from
the Edge Guide.
Hopper
Figure 4-39. Removing the Edge Guide
When installing the Hopper, make sure to install the Compression
Spring under the rib as shown below.
Rib
Figure 4-40. Assembling the Hopper
Whenever the Hopper is removed/replaced, the required
A D J U S T M E N T
R E Q U I R E D
adjustments must be carried out.
Chapter 5 " ADJUSTMENT" (p.110)
Revision C
Hook
Edge Guide
Compression Spring
Confidential