3.
Release the two hooks of the IS Cap Assy by rotating it to the direction of
arrow pulling out the central rib of the assy., and remove the IS Cap Assy
from the Case Cleaner.
Case Cleaner
Back
Hook
Rib
Figure 4-59. Disassembling the Cap Assy (2)
4.
Remove the Cleaner Cap Spring from the dowels of the IS Cap Assy.
IS Cap Assy
Figure 4-60. Disassembling the Cap Assy (3)
DISASSEMBLY/ASSEMBLY
IS Cap Assy
Cleaner Cap Spring
Dowel
Disassembling the Printer Mechanism
When installing the Foam Cap Side, align the notchs of the
Foam Cap Side with the ribs of the Case Cleaner, and insert
them without any gap. (See Fig.4-61.)
When installing the IS Cap Assy, install the Cleaner Cap Spring
to the dowels of the Case Cleaner.
Ribs of Foam Cap Side
Figure 4-61. Assembling the Cap Assy (1)
When installing the Blade Wiper and the Felt Wiper, align the
dowels of the Blade Wiper with the positioning holes of the Felt
Wiper.
Blade Wiper
Figure 4-62. Assembling the Cap Assy (2)