Characteristics:
Transmission speed
Transmission mode
Connectors
Wavelength
Core diameter
Outer diameter
Light source
Cable lengths
Signal attenuation
Note
No autonegotiation
With optical transmission, the full duplex mode and transmission speed cannot be changed. For
this reason, the autonegotiation function cannot be selected.
GI-PCF
For segment lengths longer than 100 m, you can use GI-PCF cables. Note the information of the
manufacturer.
5.6.3

Push-pull connector for IRT-PRO devices

Push-pull connector technology
With the following devices, the connection to Industrial Ethernet makes use of the PROFINET-
compliant push-pull connector technology:
• X204IRT PRO
• X202-2P IRT PRO
• X201-3P IRT PRO
SCALANCE X-200
Operating Instructions, 11/2021, C79000-G8976-C284-15
with POF
with PCF
with POF
with PCF
minimum
maximum segment length
with POF
with PCF
5.6 Attachment to Industrial Ethernet
100 Mbps
100Base-FX analogous to IEEE 802.3
SC RJ jacks
650 nm
980 μm
200 μm
1000 μm
230 μm
LED
0 m
50 m for POF
100 m for PCF
0.230 dB/m
0.01 dB/m
Connecting up
77