3.5
The LEDs
3.5.1
LED display when the device starts up
When the X-200 starts up, the LEDs light up in the following sequence:
• The green power LED lights up immediately after turning on the device.
• The LEDs of the Ethernet connectors light up for approximately 6 seconds.
• When the Ethernet LEDs go off, the red fault LED is lit for approximately 20 seconds.
• Following this, after approximately 2 seconds the correct link status is displayed.
The X-200 is now ready for operation.
3.5.2
Power LED "L" (green/yellow LED)
The power LED shows the status of the power supply on the X-200 IE switch. The power LED can
light up either green or yellow. The meanings of the display are as follows:
LED color
LED status
Green
Lit
Yellow
Lit
-
Off
Note
The following devices do not have a redundant power supply:
• X201-3P IRT PRO
• X202-2P IRT PRO
• X204IRT PRO
3.5.3
Fault LED "F" (yellow/red LED)
The fault LED indicates a fault/error on the X-200. If the X-200 detects an error, the signaling
contact is opened at the same time assuming that the response of the signaling contact was not
configured differently.
SCALANCE X-200
Operating Instructions, 11/2021, C79000-G8976-C284-15
Meaning
Both power supplies are connected; in other words, redundant power supply.
Only one power supply is connected or the voltage is < 14 VDC at one of the two
connectors.
No power supply is connected or the voltage is < 14 VDC or with TS devices < 8 VDC.
Description of the device
3.5 The LEDs
31