Led Error Codes; Jumper Settings - TC Electronic FINALIZER Service Manual

Hide thumbs Also See for FINALIZER:
Table of Contents

Advertisement

LED Error Codes:

In case of error three LED's at the main board version PC12001-3 (LD1, LD2, LD3) might show an error code.
LD1
LD2
LD3
off
off
off
The MPU is running OK
on
on
on
The program encountered an error while checking its own code

Jumper settings:

Jumper settings on main board version PC12001-3: JP2 unused. JP4 & JP5 controls boot mode:
JP4
JP5
Boot from Flash (normal mode)
__________________________________________________________________________________________________________________________________________________________________________________________________
TC Electronic A/S
Code explanation
JP4
JP5
Boot from PCMCIA (only used at factory)
Finalizer Service manual
Comment
All LED's must blink once at power up
Boot sector in Flash is corrupted. Reload boot or replace Flash