Checking The Electrical Parts - Sanyo SPW-XR253GH56 Technical Data & Service Manual

Table of Contents

Advertisement

(4)

Checking the Electrical Parts

1
Power transformer (TR1) ................. Indoor unit *Measure the coil resistance.
Primary
Secondary
Refer to "1-3 Other component specifications".
2
Power transformer (TR) ............ Outdoor unit
Primary
Secondary
3
Indoor fan motor (FMI) ............... Indoor unit
Measure the resistance between each terminal of 9P (WHT) socket
connected to the indoor fan motor.
Refer to "1–2–(A) Major component specifications".
4 Outdoor fan motor (FMO) ........... Outdoor unit
Measure the resistance in the same manner as explained above 3.
Refer to "1–2–(B)Major component specifications".
5
Fan motor capacitor ............ Both in indoor and outdoor unit
Remove the lead wires from the capacitor terminals,
and then place a probe on the capacitor terminals as
shown in Fig. 30. Observe the deflection of the pointer,
setting the resistance measuring range of the multimeter
to the maximum value.
The capacitor is "good" if the pointer bounces to a great
extent and then gradually returns to its original position.
NOTE
The range of deflection and the deflection time differ
according to the capacity of the capacitor.
; Measure the resistance between No.1 and No.3
(WHT lead wires) terminals of 3P (WHT) socket
connected to power transformer.
14V ; Measure the resistance between No.1 and No.2
(RED lead wires).
10V ; Measure the resistance between No.3 and No.4
(BRN lead wires).
; Measure the resistance between No.1 and No.3
(WHT lead wires) terminals of 3P(WHT) socket jointed
to power transformer.
14 V ; Measure the resistance between No.1 and No.2
(BRN lead wires).
Refer to "1-3 Other component specifications".
IV - 39
4. Service procedures
*Measure the coil resistance.
*Measure the coil resistance.
*Measure the coil resistance.
Fan motor
Capacitor
Fig. 30
1
2
Multimeter
3
4
5
0643_X_S
SM830080