1-3 Other Component Specifications
Outdoor Unit
MODEL NO.
Outdoor Unit
Power Transformer
Rated
Primary
Secondary
Coil resistance
Thermal cut off temperature
Thermistor (Coil sensor) : TH6, 7
Coil resistance
Thermistor (Discharge gas sensor) : TH8
Coil resistance
Relay (Comp. Magnetic Contactor)
Coil rated
Contact rating
Coil resistance (at 25 °C)
Solenoid coil or 4 way valve
4 way valve
Solenoid coil
VAC, Hz
WHT – WHT : 300
°C
PBC - 41E - S26
–10 °C : 23.7
kΩ
– 5 °C : 18.8
0 °C : 15.0
5 °C : 12.1
60 °C : 13.8
kΩ
70 °C : 9.7
75 °C : 8.2
80 °C : 7.0
85 °C : 5.9
VAC
VAC, A
I - 57
SPW-CR253GHL5, SPW-CR253GHL8
ATR - I65B
230 V, 50 Hz
14 V, 0.4 A
,
145
,
,
,
,
,
PTC - 51H - S1
,
,
,
,
,
FC - 1SZ607
220 - 240 V
440 V, 13 A
CHV - 0201
CHV - 01AJ504D1
1. Specifications
BRN – BRN : 2.2
PBC - 41E - S4
10 °C : 9.7
20 °C : 6.5
30 °C : 4.4
40 °C : 3.1
45 °C : 2.6
90 °C : 5.1
100 °C : 3.8
110 °C : 2.8
120 °C : 2.2
130 °C : 1.7