Heating mode:
Information requirements for heat pumps
Model(s):EVRO335Y6;
Test matching indoor units form1, non-duct: 6×EVRI56CSTZ2
Outdoor side heat exchanger of air conditioner:air
Indoor side heat exchanger of air conditioner:air
Idication if the heater is equipped with a supplementary heater:no
If applicable:driver of compressor:electric motor
Parameters shall be declared for the average heating season,parameters for the warmer and colder heating seasoms are optional
Item
Symbol
P
Rated heating capacity
rated,h
Declared heating capacity for part load at indoor teperature 20℃ and
outdoor temperatures T
P
T
=-7℃
dh
j
T
=+2℃
P
dh
j
T
=+7℃
P
dh
j
T
=+12℃
P
dh
j
T
=bivalent
biv
P
dh
temperature
T
=operation
OL
P
dh
temperature
Bivalent temperature
T
biv
Degradation co-efficient
C
dh
for heat pumps(**)
Power consumption in modes other than "active mode"
P
Off mode
OFF
Thermosat-off mode
P
TO
P
Crankcase heater mode
CK
Capacity control
Sound power
L
WA
level,outdoor
GWP of the refrigerant
EAS ELECTRIC Smart Technology P.I. Canyada Codonyers C/Principal, nº4 46620 PICASSENT www.easelectric.es
Contact details:
(*)
(**)If C
is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25
dh
Where information relates to multi-split heat pumps,the test result and performance data may be obtained on the basis of performance of the outdoor
unit ,with a combination of indoor unit(s) recommended by the manufacturer or importer
Value
Unit
kW
33.5
j
21.434
kW
12.702
kW
8.381
kW
4.622
kW
22.589
kW
22.589
kW
-10
0.25
0.04
kW
0.04
kW
0.04
kW
Other items
variable
81
dB
2088
(100years)
kg CO
2 eq
Item
Seasonal space heating
energy efficiency
Declared coefficient of performance or gas utilisation
efficiency/auxiliary energy factor for part load at given outdoor
T
=-7℃
j
T
=+2℃
j
T
=+7℃
j
T
=+12℃
j
T
=bivalent temperature
biv
T
=operation temperature
OL
Back-up heating capacity(*)
Type of energy input
Standby mode
For air-to-air heat pump:air
flow rate,outdoor measured
32
Symbol
Value
η
143.4
s,h
temperatures T
j
COP
2.53
d
3.45
COP
d
COP
5.21
d
5.81
COP
d
COP
2.21
d
COP
2.21
d
Supplementary heater
elbu
0.04
P
0.04
SB
11300
Table.10
Unit
%
--
--
--
--
--
--
kW
kW
3
m
/h
V.2