Heating mode:
Information requirements for heat pumps
Model(s):EVRO260Y6;
Test matching indoor units form, Duct:2×EVRI45CSTZ2+2×EVRI90CSTZ2;
Outdoor side heat exchanger of air conditioner:air
Indoor side heat exchanger of air conditioner:air
Idication if the heater is equipped with a supplementary heater:no
If applicable:driver of compressor:electric motor
Parameters shall be declared for the average heating season,parameters for the warmer and colder heating seasoms are optional
Item
Symbol
P
Rated heating capacity
rated,h
Declared heating capacity for part load at indoor teperature 20℃ and
outdoor temperatures T
T
=-7℃
P
dh
j
P
T
=+2℃
dh
j
T
=+7℃
P
dh
j
T
=+12℃
P
dh
j
T
=bivalent
biv
P
dh
temperature
T
=operation
OL
P
dh
temperature
T
Bivalent temperature
biv
Degradation co-efficient
C
dh
for heat pumps(**)
Power consumption in modes other than "active mode"
P
Off mode
OFF
P
Thermosat-off mode
TO
Crankcase heater mode
P
CK
Capacity control
Sound power
L
WA
level,outdoor
GWP of the refrigerant
EAS ELECTRIC Smart Technology P.I. Canyada Codonyers C/Principal, nº4 46620 PICASSENT www.easelectric.es
Contact details:
(*)
(**)If C
is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25
dh
Where information relates to multi-split heat pumps,the test result and performance data may be obtained on the basis of performance of the outdoor
unit ,with a combination of indoor unit(s) recommended by the manufacturer or importer
Value
Unit
26
kW
j
13.78
kW
8.449
kW
5.694
kW
4.224
kW
13.78
kW
13.601
kW
-7
0.25
0.04
kW
0.04
kW
0
kW
Other items
variable
77
dB
(100years)
kg CO
2088
2 eq
Item
Seasonal space heating
energy efficiency
Declared coefficient of performance or gas utilisation
efficiency/auxiliary energy factor for part load at given outdoor
T
=-7℃
j
T
=+2℃
j
T
=+7℃
j
T
=+12℃
j
T
=bivalent temperature
biv
T
=operation temperature
OL
Back-up heating capacity(*)
Type of energy input
Standby mode
For air-to-air heat pump:air
flow rate,outdoor measured
28
Symbol
Value
η
133.4
s,h
temperatures T
j
3.05
COP
d
4.18
COP
d
7.23
COP
d
8.75
COP
d
3.05
COP
d
COP
2.02
d
Supplementary heater
elbu
0
0.04
P
SB
10000
Table.6
Unit
%
--
--
--
--
--
--
kW
kW
3
m
/h
V.2