PERFORMANCE DATA SHEET
Performance Data - Pentair Whole House Filters
Model
Replacement
PC600-P
PC600-R
PC1000-P
PC1000-R
This system has been tested according to NSF/ANSI 42 for the reduction of the substances listed below. The concentration of
the indicated substances in the water entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in NSF/ANSI 42.
NSF/ANSI 42
Chlorine Reduction,
Free Available
Performance Data - Pentair Whole House Filters
Model
Accumulated
Volume (Gallons)
PC600-P
650,885
PC1000-P
1,301,770
PC1354-P
1,952,655
Statements: Testing was performed under standard laboratory
conditions, actual performance may vary. Filter usage must
comply with all state and local laws. Filter is only to be used with
cold water. All contaminants reduced by this filter are listed. Not
all contaminants listed may be present in your water. Filter does
not remove all contaminants that may be present in tap water.
See owner's manual for general installation conditions and needs
as well as manufacturer's limited warranty.
14 •
WHOLE HOUSE WATER FILTER SYSTEM
Max Operating
Rated Capacity
Pressure
25-80 PSI
662,400 gallons
25-80 PSI
1,324,800 gallons
Influent Challenge
Minimum Required
Chlorine
Reduction
2 mg/L ±10%
≥50%
Chlorine, Free
Available (mg/L)
Influent
2.05
2.05
2.05
Operating
Rated
Temp Range
Flow
36°F – 120°F
8 GPM
36°F – 120°F
12 GPM
Average Reduction %
95.93%
Flow Rate
(GPM)
Effluent 1
0.07
8 GPM
0.07
12 GPM
0.07
17 GPM
Rated Pressure Drop
(At Rated Flow)
13 PSI
13 PSI
Results
Pass
Reduction %
96.6%
96.6%
96.6%
Certified By IAPMO R&T to NSF/
ANSI Standard 42 for the reduc-
tion of Chlorine Taste & Odor,
structural integrity & NSF/ANSI 61
for material safety.