MAINTENANCE
RECOMMENDED FILLING INSTRUCTIONS FOR HYDRAULIC
RESERVOIRS
When filling or checking the oil level, the unit should
be parked on a level surface., shut "OFF", and
allow sufficient time to cool to ambient temperature.
Use caution when removing the pressurized
breather. Do n ot place face o ver opening when
removing breather.
If your reserv oir has two sight
glasses: The
reservoir should be filled to the top of the lower
sight glass on the side of the tank. Do not overfill.
The reservoir has been overfilled when oil is visible
in the upper sight glass. If tank has too much oil, the
excess may be expelled through the pressurized
breather.
If your reservoir has one sight glass/temperature
gage: The reservoir should be filled to the center
of the sight gla ss on the side of th e tank. Do not
over-fill. If the t ank has too much oil, the excess
may be expelled through the pressurized breather
REPLACING IN-TANK HYDRAULIC FILTER
Loosen the four bolts on the top cover of the filter
housing. Turn cover counter-clockwise until cover is
free. Remove and replace filter. Replace top cover
and cover bolts in opposite order as removed.