Page 3
8-channel: 8-channel: 10, 100, 300 10, 100, 300 12-channel: 10, 100, 300 12-channel: 10, 100, 300 Запасная Запасная Spare Spare Ersatzteile Ersatzteile Piéces Piéces Repuestos Repuestos Parti di Parti di част част ь ь Parts Parts détachées détachées...
PRODUCT PRODUCT DESCRIPTION DESCRIPTION ® ® Your new Biohit Proline Your new Biohit Proline Plus is an autoclavable air displacement Plus is an autoclavable air displacement ® ® pipette. The attra pipette. The attractive and ergonomical design of the Proline...
BIOHIT BIOHIT OPTIFIT OPTIFIT TIPS TIPS The full range of Biohit pipette tips are recommended for use with The full range of Biohit pipette tips are recommended for use with ® ® Biohit Proline Biohit Proline Plus pipettes. Biohit stand Plus pipettes.
, carousel or linear stand whe r linear stand when not in use. n not in use. Cat.No. Cat.No. Product Product 725600 Biohit Biohit Carousel Carousel Stand Stand pipettes pipettes 72561 725610 Biohi Biohit Pipette...
.2 .2. Sealing an Sealing and ejecting tips d ejecting tips To ensure the maximum accuracy and precision Biohit tips are To ensure the maximum accuracy and precision Biohit tips are ® ® recommended to be used with Proline recommended to be used with Proline Plus pipettes.
(See Chapter 2 of over-aspiration. (See Chapter 2 for ordering information.) The Biohit for ordering information.) The Biohit Filter Foreceps should be used to Filter Foreceps should be used to...
Page 11
8.2. Reverse erse pipetting pipetting (Fig. 7) (Fig. 7) onto onto pipet pipette cone. cone. Press Press operating button operating button second st second stop. Place the Place the just under just under surface of face of the liquid the liquid (2-3 (2-3...
If the pipette is used daily it is recommended to clean/decontaminate and check the performance of the pipette clean/decontaminate and check the performance of the pipette every three months. Biohit also provides complete repair and every three months. Biohit also provides complete repair and recalibration ser...
Page 13
(cylinder) and the piston (4) with Biohit Proline Biocontrol, (cylinder) and the piston (4) with Biohit Proline Biocontrol, ethanol (70%), isopropanol (60%) or mild detergent and soft ethanol (70%), isopropanol (60%) or mild detergent and soft...
Page 15
(ISO 8655-1.) (ISO 8655-1.) Note Note : Biohit speci : Biohit speci fi fi cations are achieved in strictly controlled condi- cations are achieved in strictly controlled condi- tions (ISO 8655-6). The user should establish own speci tions (ISO 8655-6).
Page 16
: Recalibration is recommended if reverse pipetting technique is used. is used. Note Note : Biohit offers accredited calibration service. Please contact : Biohit offers accredited calibration service. Please contact your local Biohit representative for further information. your local Biohit representative for further information. ...
Page 17
Pipette Pipette damaged damaged Return Return your your Biohit service Biohit service representative representative for servicing for servicing Pipette Pipette Incorrect Incorrect operation operation Follow Follow instructions instructions established established...
Should your years against defects in materials and workmanship. Should your pipette fail to function at any time, please contact your local Biohit pipette fail to function at any time, please contact your local Biohit representative.
Page 19
Specifications Specifications ® ® Biohit Proline Biohit Proline Plus single-, 8- and 12-channel pipettes Plus single-, 8- and 12-channel pipettes Cat.No. Cat.No. Channels Channels olume olume Inacc. Inacc. Impr. Impr. range range volume volume μ μ...
Page 20
Biohit no es responsable en caso de errores u omisiones, y se Biohit no es responsable en caso de errores u omisiones, y se reserva el derecho de aplicar cambios sin previo aviso.
Need help?
Do you have a question about the Proline Plus and is the answer not in the manual?
Questions and answers