English
23 Troubleshooting Guide
23.1 Blower
Always remove the battery before carrying out any inspection, cleaning or maintenance.
Condition
LEDs on
Battery
Blower does not start
when switched on.
1 LED flashes
green and six
long beeps are
emitted.
1 LED glows
red.
4 LEDs flash
red and a rapid
succession of
short beeps is
emitted.
3 LEDs glow
red.
3 LEDs flash
red.
26
Cause
Remedy
No electrical contact
► Remove the battery, @ 14.2.
between blower and
► Visually check the electrical contacts on the battery-side
battery.
plug and on the battery.
► Reinsert the battery, @ 14.1.
Battery has low
► Charge the battery as described in its instruction manual.
charge.
Battery too hot / too
► Allow the battery to warm up or cool down gradually at
cold.
ambient temperatures of about 50 °F to 68 °F (10 °C to
20 °C).
Malfunction in
► Remove and reinsert the battery, @ 14.
battery.
► Switch on the blower, @ 15.1.
► If the LEDs continue to flash, do not attempt to use.
The battery has a malfunction and must be replaced.
The trigger switch is
► Switch on the blower as described in this instruction
already depressed
manual, @ 15.1.
before the retaining
latch is pushed
forward.
Blower too hot.
► Allow the blower to cool down.
Malfunction in
► Remove and reinsert the battery, @ 14
blower.
► Switch on the blower, @ 15.1.
► If the LEDs still flash, do not attempt to use.
The blower has a malfunction and must be checked by a
servicing dealer.
23 Troubleshooting Guide
0458-724-8201-A