Dell EMC PowerEdge R730xd Owner's Manual page 156

Hide thumbs Also See for EMC PowerEdge R730xd:
Table of Contents

Advertisement

k. Cooling fan assembly
l.
Cooling shroud
m. Power supply unit(s)
3. Reconnect all cables to the system board.
Ensure that the cables inside the system are routed along the chassis wall and secured using the cable securing
NOTE:
bracket.
4. Follow the procedure listed in the After working inside your system section.
5. Import your new or existing iDRAC Enterprise license. For more information, see Integrated Dell Remote Access Controller
User's Guide, at Dell.com/esmmanuals.
6. Ensure that you:
a. Use the Easy Restore feature to restore the Service Tag. For more information, see the Easy restore section.
b. If the Service Tag is not backed up in the backup flash device, enter the Service Tag manually. For more information, see
the Entering the Service Tag section.
c. Update the BIOS and iDRAC versions.
d. Re-enable the Trusted Platform Module (TPM). For more information, see the Re-enabling the Trusted Platform Module
(TPM) section.
Related tasks
Installing the cable retention bracket
Installing the PCIe card holder
Installing the hard drive tray
Installing the integrated storage controller card
Replacing the optional internal USB memory key
Installing the optional internal dual SD module
Installing expansion card risers
Installing a heat sink
on page 106
Installing a processor
on page 104
Installing memory modules
Installing the network daughter card
Installing the cooling fan assembly
Installing the cooling shroud
Installing an AC power supply unit
Installing a DC power supply unit
Entering the system Service Tag by using System Setup
If Easy Restore fails to restore the Service Tag, use System Setup to enter the Service Tag.
Steps
1. Turn on the system.
2. Press F2 to enter System Setup.
3. Click Service Tag Settings.
4. Enter the Service Tag.
You can enter the Service Tag only when the Service Tag field is empty. Ensure that you enter the correct
NOTE:
Service Tag. After the Service Tag is entered, it cannot be updated or changed.
5. Click OK.
6. Import your new or existing iDRAC Enterprise license.
For more information, see the Integrated Dell Remote Access Controller User's Guide at
156
Installing and removing system components
on page 111
on page 108
on page 78
on page 114
on page 140
on page 136
on page 130
on page 97
on page 138
on page 89
on page 76
on page 145
on page 150
www.dell.com/poweredgemanuals
.

Advertisement

Table of Contents
loading

Table of Contents