ACS 800 type
Frame
size
690 V units
-0070-7
R6
-0100-7
R6
-0120-7
R6
-0140-7
R7
-0170-7
R7
-0210-7
R7
-0260-7
R7
-0320-7
R8
-0400-7
R8
-0440-7
R8
-0490-7
R8
-0550-7
R8
-0610-7
R8
P
Maximum braking power of the drive with the specified resistor(s). The drive and the chopper will withstand this braking power for
br5
5 seconds per minute.
P
The drive and the chopper will withstand this braking power for 10 seconds per minute.
br10
P
The drive and the chopper will withstand this braking power for 30 seconds per minute.
br30
P
The drive and the chopper will withstand this continuous braking power. The braking is considered continuous if the braking time
brcont
exceeds 30 s.
Note: Check that the braking energy transmitted to the specified resistor(s) in 400 seconds does not exceed E
R
Resistance value for the resistor assembly. Note: This is also the minimum allowed resistance for the brake resistor.
E
Short energy pulse that the resistor assembly withstands every 400 seconds. This energy will heat the resistor element from
R
40 °C (104 °F) to the maximum allowable temperature.
P
Continuous power (heat) dissipation of the resistor when placed correctly. Energy E
Rcont
*
ACS800-Ux types only
1)
240 kW possible if ambient temperature is below 33 °C (91 °F)
2)
160 kW possible if ambient temperature is below 33 °C (91 °F)
3)
630 kW possible if ambient temperature is below 33 °C (91 °F)
4)
450 kW possible if ambient temperature is below 33 °C (91 °F)
5)
135 kW possible if ambient temperature is below 33 °C (91 °F)
6)
148 kW possible if ambient temperature is below 33 °C (91 °F)
7)
160 kW possible if ambient temperature is below 33 °C (91 °F)
Braking power of the chopper and the
drive
5/60 s
10/60 s
30/60 s
P
P
P
br5
br10
br30
(kW)
(kW)
(kW)
-
-
-
-
-
-
-
-
-
5)
125
110
90
6)
125
110
90
6)
125
110
90
7)
135
120
100
300
300
300
375
375
375
430
430
430
550
400
315
550
400
315
550
400
315
Brake resistor(s)
Type
P
brcont
(kW)
45
SAFUR90F575
55
SAFUR80F500
75
SAFUR80F500
75
SAFUR80F500
75
SAFUR80F500
75
SAFUR80F500
80
SAFUR80F500
260
SAFUR200F500
375
SAFUR200F500
385
SAFUR200F500
225
2xSAFUR125F500
225
2xSAFUR125F500
225
2xSAFUR125F500
R
R
E
R
(ohm)
(kJ)
8.00
1800
6.00
2400
6.00
2400
6.00
2400
6.00
2400
6.00
2400
6.00
2400
2.70
5400
2.70
5400
2.70
5400
2.00
7200
2.00
7200
2.00
7200
PDM code 00096931-G
.
R
dissipates in 400 seconds.
Resistor braking
99
P
Rcont
(kW)
4.5
6
6
6
6
6
6
13.5
13.5
13.5
18
18
18

Advertisement