12. Disposal and recycling
The device is supplied in packaging to avoid trans-
port damages. This packaging is raw material and
can thus be used again or can be reintegrated into
the raw material cycle.
The device and its accessories are made of differ-
ent materials, such as metals and plastics. Take de-
fective components to special waste disposal sites.
Check with your specialist dealer or municipal admin-
istration!
13. Troubleshooting
Fault
Possible cause
The compressor
Mains voltage is not available.
does not start.
Mains voltage is too low.
Outside temperature is too low.
Motor is overheated.
The compressor
The safety valve leaks.
starts but there is no
pressure.
The seals are damaged.
The drain screw for condensate leaks.
The compressor
The hose connections have a leak.
starts, pressure is
shown on the pres-
A quick coupling has a leak.
sure gauge, but the
tools do not start.
Insufficient pressure set on the pres-
sure regulator.
12
Remedy
Check the cable, mains plug, fuse and socket.
Make sure that the extension cable is not too long.
Use an extension cable with large enough wires.
Never operate with an outside temperature of
below +5 °C.
Allow the motor to cool down. If necessary, reme-
dy the cause of the overheating.
Contact your local service centre. Only allow qual-
ified personnel to carry out repairs.
Check the seals and have any damaged seals
replaced by a service centre.
Tighten the screw by hand. Check the seal on the
screw and replace if necessary.
Check the compressed air hose and tools and
replace if necessary.
Contact your local service centre. Only allow qual-
ified personnel to carry out repairs.
Increase the set pressure with the pressure regu-
lator.
Need help?
Do you have a question about the HC25Si and is the answer not in the manual?
Questions and answers