How To Enter "Data Pass-Through Mode; Wizs2E Configtool; Reading Module Information - Wiznet W5500S2E User Manual

Ethernet module
Table of Contents

Advertisement

4.
If TCP connection is close. It is need to reconnected using AT command.
5.
If parameters changes are needed, it can be configured directly using AT command.
Note: "AT data transfer command mode" is supported by firmware version is 2.3 or above

4.3 How to enter "Data pass-through mode"

There is three ways for entering the "data pass-through mode".
1
By AT command (For details, please refer to chapter 6 "RESET & "EXIT" command)
2
Web page (For details, please refer to chapter 7)
3
WIZS2E ConfigTool utility (For details, please refer to chapter 5)

5 WIZS2E ConfigTool

WIZS2E ConfigTool is Windows
used to read, configure all settings and firmware updating for WIZS2E modules.
Note: It is recommended to turn off the firewall before using the ConfigTool. Also, there
must no conflict of IP address in the same LAN.

5.1 Reading module information

When starting ConfigTool or clicking the
search all WIZS2E modules that have connected in the same LAN. Figure below shows the
search result with one module in the network. By selecting the MAC address in the list,
you can read and configure all the parameters of this module.
W5500S2E user manual
W5500S2E serial to Ethernet module
compatibles to all WIZS2E modules. It can be
® software
Figure 5-1 WIZS2E ConfigTool "Basic Settings"
16
button, WIZS2E ConfigTool will