Complete Inspection; Pre-Trip Diagnosis; Table 5-1 Pre-Trip Selection Menu - Carrier 69NT40-541-001 Operation And Service

Container refrigeration units
Table of Contents

Advertisement

DataCORDER
a. Check and, if required, set the DataCORDER Configuration in accordance with desired recording parame-
ter. Refer to
Section
b. Enter a "Trip Start". To enter a "trip Start", do the fol lowing:
1. Depress the ALT MODE key and scroll to Code dC30.
2. Depress and hold the ENTER key for five seconds.
3. The "Trip Start" event will be entered in the DataCORDER.
5.7.4

Complete Inspection

Allow unit to run for 5 minutes to stabilize conditions and perform a pre-trip diagnosis in accordance with the
TRIP
DIAGNOSIS.
5.8

PRE-TRIP DIAGNOSIS

Pre-trip inspection should not be per formed with critical temperature cargoes in the container.
When Pre-Trip key is pressed, dehumidification and bulb mode will be deactivated. At the com-
pletion of Pre-Trip activity, dehumidification and bulb mode must be reactivated.
Pre-Trip diagnosis provides automatic testing of the unit components using internal measurements and compari-
son logic. The program will provide a "PASS" or "FAIL" display to indicate test results.
The testing begins with access to a pre-trip selection menu. The user may have the option of selecting one of three
automatic tests (depending on software revision installed). These tests will automatically perform a series of indi-
vidual pre-trip tests. The user may also scroll down to select any of the individual tests. The contents of the menus
are as follows:
AUTO OR AUTO 1
P, P1, P2, P3, P4, P5, P6, rSLts
A detailed description of the pre-trip test codes is listed in
selection process will terminate automatically. However, dehumidification and bulb mode must be reactivated man-
ually if required.
Scrolling down to the "rSLts" code and pressing ENTER will allow the user to scroll through the results of the last
pre-trip testing run. If no pre-testing has been run (or an individual test has not been run) since the unit was pow-
ered up "----" will be displayed.
To start a pre-trip test, do the following:
1. Prior to starting tests, verify that unit voltage (Function Code Cd 07) is within tolerance and unit amperage
draw (Function Codes Cd04, Cd05, Cd06) is within expected limits. Otherwise, tests may fail incorrectly.
2. All alarms must be rectified and cleared before starting tests.
T-316
4.6.3.
CAUTION
!
CAUTION
!
Table 5–1 Pre-Trip Selection Menu
P, P1, P2, P3, P4, P5, P6, P7,
P8, P9, P10, rSLts
AUTO 2
P, P1, P2, P3, P4, P5, P6, P7,
Table
4–7. If no selection is made, the pre-trip menu
NOTE
5–6
PRE-
AUTO 3
P8, rSLts

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

69nt40-541-00269nt40-541-00369nt40-541-00469nt40-541-00569nt40-541-00669nt40-541-007 ... Show all

Table of Contents