Carrier 69NT40-541-001 Operation And Service page 22

Container refrigeration units
Table of Contents

Advertisement

2.3.8
Remote Monitoring
The unit may be fitted with a remote monitoring receptacle. This item allows connection of remote indicators for
COOL, DEFROST and IN RANGE. Unless otherwise indicated, the receptacle is mounted at the control box location.
2.3.9
Communications
The unit may be fitted with a communications interface module. The communications interface module is a slave
module which allows communication with a master central monitoring station. The module will respond to commu-
nication and return information over the main power line. Refer to the ship master system technical manual for fur-
ther information.
2.3.10
Compressor
The unit is fitted with a single speed reciprocating compressor.
2.3.11
Condenser Coil
The unit is fitted with a 3 row coil using 7mm tubing.
2.3.12
Autotransformer
An autotransformer may be provided to allow operation on 190/230, 3phase, 50/60 hertz power. The autotrans-
former raises the supply voltage to the nominal 380/460 volt power required by the base unit. The autotransformer
may also be fitted with an individual circuit breaker for the 230 volt power. If the unit is equipped with an autotrans-
former and communications module, the autotransformer will be fitted with a transformer bridge unit (TBU) to assist
in communications.
2.3.13
Temperature Recorder
The units may be fitted with an electronic temperature recording device manufactured by the Partlow Corporation.
2.3.14
Gutters
Rain gutters may be fitted over the control box and recorder section to divert rain away form the controls. The dif-
ferent gutters include standard length bolted gutters, extended length gutters and riveted gutters.
2.3.15
Handles
The unit may be equipped with handles to facilitate access to stacked containers. These handles may include fixed
handles (located at the sides of the unit) and/or a hinged handle at the center (attached to the condenser coil cover).
2.3.16
Thermometer Port
The unit may be fitted with ports in the front of the frame for insertion of a thermometer to measure supply and/or
return air temperature. If fitted, the port(s) will require a cap and chain.
2.3.17
Water Cooling
The refrigeration system may be fitted with a water-cooled condenser. The condenser is constructed using copper-
nickel tube for sea water applications. The water-cooled condenser is in series with the air-cooled condenser and
replaces the standard unit receiver. When operating on the water-cooled condenser, the condenser fan is deacti-
vated by either a water pressure switch or condenser fan switch.
2.3.18
Back Panels
Back panel designs that may be fitted include panels of aluminum and stainless steel. Panels may have access
doors and/or hinge mounting.
2.3.19
460 Volt Cable
Various power cable and plug designs are available for the main 460 volt supply. The plug options tailor the cables
to each customers requirements.
2.3.20
230 Volt Cable
Units equipped with an autotransformer require an additional power cable for connection to the 230 volt source. Vari-
ous power cable and plug designs are available. The plug options tailor the cables to each customers requirements.
2.3.21
Cable Restraint
Various designs are available for storage of the power cables. These options are variations of the compressor sec-
tion front cover.
T-316
2–2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

69nt40-541-00269nt40-541-00369nt40-541-00469nt40-541-00569nt40-541-00669nt40-541-007 ... Show all

Table of Contents