3.1.6
Water-Cooled Condenser Section
The water-cooled condenser section
expansion valve, rupture disc, condenser pressure transducer, filter-drier, water couplings, and water pressure
switch. The water-cooled condenser replaces the standard unit receiver.
2
1
1. Sight Glass
2. Water-Cooled Condenser
3. Rupture Disc
4. Condenser Pressure Transducer
5. Quench Valve
6. Filter-Drier
(Figure
3.5) consists of a water-cooled condenser, sight glass, quench
Figure 3.5 Water-Cooled Condenser Section
3
5
4
10
11
- - - - -
3–5
6
7. Liquid Line Service Valve
8. Moisture/Liquid Indicator
9. Coupling (Water In)
10. Self Draining Coupling (Water Out)
11. Water Pressure Switch
7
8
9
T-316