SERVICE PROCEDURES
Continued
Sandpaper
Figure 28 - Sanding Rotor
14
IGNITION CONTROL ASSEMBLY
WARNING: High voltage!
1. Unplug heater.
2. Remove side cover screws (4) using 5/16" nut-
driver to expose ignition control assembly.
3. Remove fuse cover (see Figure 29).
4. Remove fuse from fuse clips (see Figure 29).
5. Replace fuse with fuse of the same type and
rating (GMA-10). Do not substitute a fuse
with a higher current rating.
6. Replace fuse cover (see Figure 29).
7. Replace side cover (see Figures 16 or 17,
page 10).
Fuse Clips
Figure 29 - Replacing Fuse
Fuse
Cover
Fuse
114278-01C