B. Chimney Diagram
C
V
B
J
B
V
D
V
V
= VENT TERMINAL
A
= 12 inches.................clearances above grade, veranda, porch,
B
= 12 inches.................clearance to window or door that may
C
= 18 inches.................clearance below an unventilated/ven-
= 18 inches .................clearance below an unventilated/ven-
= 42 inches .................clearance below a vinyl soffi t with non-
= 42 inches .................clearance below a vinyl soffi t with vinyl
D
= 6 inches...................clearance to outside corner
E
= 6 inches...................clearance to inside corner
F
= 3 ft. (Canada) ..........not to be installed above a gas meter/
G
= 3 ft ...........................clearance to gas service regulator vent
H
= 12 inches.................clearance to non-mechanical (unpow-
i
= 3 ft. (U.S.A.)
6 ft. (Canada) ...........clearance to a mechanical (powered)
All mechanical air intakes within 10 feet of a termination cap must
be a minimum of 3 feet below termination.
J
= 7 ft. ......................... On public property: clearance above
A vent shall not terminate directly above a sidewalk or paved drive-
way which is located between two single family dwellings and serves
both dwellings.
K
= 6 inches................. clearance from sides of electrical
L
= 12 inches................ clearance above electrical service
Location of the vent termination must not interfere with access to the
electrical service.
M
= 24 inches ....... clearance under veranda, porch, deck, balcony or
overhang
42 inches ..... vinyl or composite overhang
Permitted when veranda, porch, deck or balcony is fully open on a
minimum of 2 sides beneath the fl oor.
Figure 4.3 Minimum Clearances for Termination
20
Heat & Glo • TRUE-36-IFT, TRUE-42-IFT, TRUE-50-IFT Installation Manual • 2461-980 Rev. B • 2/17
F
B
V
G
V
A
X
= AIR SUPPLY INLET
deck or balcony
be opened, or to permanently closed
window
tilated soffi t with non-vinyl siding
tilated soffi t with vinyl siding. Requires
a vinyl protector kit (VPK-DV).TRUE-50
is not approved for use with vinyl siding
or vinyl soffi ts.
vinyl siding. TRUE-50 is not approved
for use with vinyl siding or vinyl soffi ts.
siding. Requires a vinyl protector kit
(VPK-DV). TRUE-50 is not approved
for use with vinyl siding or vinyl soffi ts.
regulator assembly within 3 feet horizon-
tally from the center-line of the regulator
outlet
ered) air supply inlet, combustion air
inlet or direct-vent termination
air supply inlet
paved sidewalk or a paved driveway.
service
H or i
X
V
H
M
V
V
H
V
= AREA WHERE TERMINAL IS NOT PERMITTED
(Spaces open only on one side and with an overhang)
TRUE-50 is not approved for use with vinyl siding or vinyl soffi ts.
N = 6 inches ........non-vinyl sidewalls
12 inches ......vinyl sidewalls
O = 18 inches .......clearance below an unventilated/ventilated soffi t
= 18 inches ......clearance below an unventilated/ventilated soffi t
= 42 inches ......clearance below a vinyl soffi t with non-vinyl siding
= 42 inches ......clearance below a vinyl soffi t with vinyl siding.
P = 8 ft.
Q
Measure vertical clearances from this surface.
Measure horizontal clearances from this surface.
CAUTION! Risk of Burns! Termination caps are HOT,
consider proximity to doors, traffi c areas or where people
may
pass or gather (sidewalk, deck, patio,
shields available. Contact your dealer.
Local codes or regulations may require different
clearances.
Vent system termination is NOT permitted in screened
porches.
Vent system termination is permitted in porch areas with
two or more sides open.
Hearth & Home Technologies assumes no responsibility
for the improper performance of the appliance when the
venting system does not meet these requirements.
Vinyl protection kits are required for use with vinyl siding.
O
N
P
R
Q
A
Covered Alcove Applications
with non-vinyl siding
with vinyl siding. Requires a vinyl protec-
tor kit (VPK-DV).
Requires a vinyl protector kit (VPK-DV).
Q
MIN
1 cap
3 feet
2 caps
6 feet
3 caps
9 feet
4 caps
12 feet
= # termination caps x 3
R
= (2 / # termination caps) x Q
MIN
MAX
CLEARANCE = 6 IN.
V
L
K
K
Electrical
V
V
Service
C
V
R
MAX
2 x Q
ACTUAL
1 x Q
ACTUAL
2/3 x Q
ACTUAL
1/2 x Q
ACTUAL
ACTUAL
etc.). Listed cap