34
Battery equalized timeout
35
Equalization interval
Equalization activated
36
immediately
Reset all stored data for PV
37
generated
power
output load energy
Maximum
current
41
(only for SP8000 Handy
Ultra model)
120min (default)
30days (default)
Enable
If equalization function is enabled in program 30, this program can
be set up. If "Enable" is selected in this program, it's to activate
battery equalization immediately and LCD main page will show
"
". If "Disable" is selected, it will cancel equalization function
until next activated equalization time arrives based on program 35
setting. At this time, "
Not reset(Default)
and
Disable (Default)
discharging
30A
25
Setting range is from 5min to 900
min. Increment of each click is 5
min.
Setting range is from 0 to 90 days.
Increment of each click is 1 day
Disable (default)
" will not be shown in LCD main page.
Reset
If selected, battery discharge
protection is disabled.
The setting range is from 30 A to
150 A. Increment of each click is
10A.
If discharging current is higher
than setting value, battery will stop
discharging. At this time, if the
utility is available, the inverter will
operate in bypass mode. If no
utility is available, the inverter will

Advertisement