Wiring Diagram With Fan (Lri3E-11 / Hri3E-11) - Regency Fireplace Products Liberty LRI3E Owners & Installation Manual

Gas insert
Hide thumbs Also See for Liberty LRI3E:
Table of Contents

Advertisement

installation
WIRING DIAGRAM - SYSTEM WITH FAN (LRI3E-11 / HRI3E-11)
911-276 - NG
911-277 - LP
911-027
911-084 - NG
911-085 - LP
911-173
911-010 - NG
911-011 - LP
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
If any of the original wire as supplied with the appliance must be replaced, it must be replaced with type CPE wire or its equivalent.
IMPORTANT: The 120V fan control module serves as the power source for this unit. The AA batteries in the battery holder are recommended as a backup in
case 120 volt power is lost within the home.
24
|
LRI3E-11 / HRI3E-11 Direct Vent Gas Insert
911-038
911-037
910-246
911-178
911-242
911-266/P
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
911-179
911-207/P
911-257
911-257

Advertisement