Electrical connections
CAUTION: THIS UNIT MUST HAVE AN EARTHING CONNECTION. ALL WIRING MUST BE COMPLIANT
WITH THE REGULATIONS IN FORCE IN THE COUNTRY OF INSTALLATION.
The unit is compatible for a single-phase 220-240 V, 50 Hz power supply .
The unit requires a flexible power cable. Connect the cable to the terminal block and let it out through a cable
gland and a cable clamp.
The unit must be connected directly to the power supply through a special magnetothermal switch.
CAUTION:
CAUTION:
4
Vmax start through light control
Through contact n.2 in figure 5, the machine can be connected to the switch of a room, which coming
on it starts the machine at maximum speed. The machine start-up and shutdown delay they can be adjusted
using the appropriate "ON DELAY" and "OFF DELAY" menus as described in the paragraph "Operation with
remote control display".
To connect the HMI remote display to the machine, use cables with a thickness between
2
0.35 mm
and 2.5 mm
To connect the product power supply, use a cable with a minimum section of
4X0.5/0.75 mm2 .
2
. Max length 100 m.
37