POSITIONING:
Position the dehumidifier unit in the center of the room to be conditioned if at
all possible. However if a damp patch is particularly apparent the outlet grille
should be pointed towards it.
NOTE: Both inlet grille and outlet grille of the dehumidifier unit must have
clear space around them and not be obstructed in anyway. For correct
installation and operation the unit inlet and outlet must have a clearance of
0.5M from all adjacent surfaces and or structures
WIRING:
Connect the power mains cable to a 13 Amp power supply. As follows:-
DRAINAGE:
Connect a 15mm inside diameter hose to the water outlet pipe. Secure the
hose using a worm drive clip. The hose should at no point be raised higher
than the outlet pipe. The hose should be ran to a permanent drain. Failure to
observe this requirement will result in flooding of the dehumidifier unit.
The CD100 may also be fitted with a water pump (optional), which is capable
of discharging the condensate water 30ft away from the unit. The water can,
therefore, be discharged into a drain some distance away.
INSTALATION
Brown
Blue
Green/Yellow
Page 4 of 12
Drawing : - TPC385
Issue
Date
Live
Neutral
Earth (ground)
: - 4
: - 24/11/16