Changing a System Fan
1. If necessary, open the chassis while the system is running to determine which
fan has failed. Never run the server for an extended period of time with the
chassis cover open.
2. Unplug the fan cable from the serverboard and remove the failed fan from the
chassis.
3. Replace the failed fan with an identical 4cm fan, available from Supermicro.
4. Push the new fan into the vacant space in the housing while making sure the
arrows on the top of the fan (indicating air direction) point in the same direction
as the arrows on the other fans.
5. Reposition the fan housing back over the two mounting posts in the system, then
reconnect the fan wires to the same fan headers on the serverboard.
6. Power up the system and check that the fan is working properly and that the
LED on the control panel has turned off. Finish by replacing the chassis cover.
Chapter 6: Advanced Chassis Setup
6-9. Fans in Housing