Master / Slave Setup - Eagle AVI Installation & Owner's Manual

Slide gate operator ul 325 class
Table of Contents

Advertisement

Master / Slave Setup

AVI
POWERED BY EAGLE
MASTER
Operator
IMPORTANT:
The 120 VAC power for the master and slave operators MUST be on the SAME circuit breaker.
It is recommended that each gate operator's initial set-up is completed (Direction of gate travel, limit nuts,
ERD reverse sensor and feature selector switches #1 - #4) before connecting the operators together.
After each operator functions individually, proceed to Master/Slave connection and operation.
#8
#9
SLAVE MASTER
+ –
+ –
Master
Operator
COMM PORT
COMM PORT
Master Operator
SELECT
SLAVE
MASTER
OPEN LEFT
OPEN RIGHT
BRAKE OFF
BRAKE ON
CLOSE TIMER OFF
CLOSE TIMER ON
OFF—ON
FEATURE SELECTOR
Switch #1 MUST be ON. Refer to
page 11 for more information
about each of the features.
SELECT
OPEN
OPENING CLOSING CLOSED
CLOSE TIMER OFF
LIMIT
LIMIT
CLOSING
OFF—ON
FEATURE SELECTOR
GATE STATUS
0
1
M/S PHASE
ERD OVERLOAD
Master Board
GND
RCVR
GND
#2
POWER
Close Timer
(Master Operator)
Use the Close Timer (Feature
Selector #4 ON) on the master
board ONLY to set the gates
closing time 1 - 60 seconds.
Clockwise increases close time.
TIMER
AVI Slide Rev - C
Opens to the Left
Connect Master and Slave Operators Together
Choose your board type (Master or Slave) and use 20
GA stranded wire. Correct polarity is VERY important.
DO NOT cross polarity. Operators will NOT function
properly if not wired correctly. Make sure to use color
coated wire.
Negative to Negative 20 AWG Wire
Positive to Positive 20 AWG Wire
NOTE: #1 & #2 switch settings are
based on the illustration above.
ACCESSORIES NOTE: Connect accessories to
the master or slave boards).
See page 16 for accessory wiring connections.
0
M/S PHASE
Opens to the Right
Jumper
1
SELECT
SELECT
SLAVE
SLAVE
MASTER
MASTER
OPEN LEFT
OPEN LEFT
OPEN RIGHT
OPEN RIGHT
OPEN
OPENING CLOSING CLOSED
BRAKE OFF
BRAKE OFF
BRAKE ON
BRAKE ON
CLOSE TIMER OFF
CLOSE TIMER OFF
CLOSE TIMER ON
CLOSE TIMER ON
OPENING
CLOSING
LIMIT
LIMIT
OFF—ON
OFF—ON
FEATURE SELECTOR
EATURE SELECTO
TIMER
ERD CONTROL
GATE STATUS
M/S PHASE NOTE: If the Master and Slave
S1 S2
FCN
0
1
ON ON
STOP N/C
ON OFF CLOSE
RESET
M/S PHASE
OFF ON
PHANTOM
OFF OFF EDGE SENSOR
MULTI FUNCTION
ERD OVERLOAD
operators are NOT communicating properly,
verify that they are on the same phase by
switching the M/S Phase jumper on either
GND
#1
RCVR
24VAC
the master or the slave unit. Make sure to
GND
reset both boards.
#2
#3
#4
#5
#6
#7
#8
#9
SLAVE MASTER
+ –
+ –
INPUT/OUTPUT
COMM PORT
COMM PORT
POWER
AVI
POWERED BY EAGLE
SLAVE
Operator
#8
#9
SLAVE MASTER
+ –
+ –
Slave
Operator
COMM PORT
COMM PORT
Slave Operator
SELECT
SLAVE
MASTER
OPEN LEFT
OPEN RIGHT
BRAKE OFF
BRAKE ON
CLOSE TIMER OFF
CLOSE TIMER ON
OFF—ON
FEATURE SELECTOR
Switch #1 MUST be OFF.
Switch #4 MUST be OFF. Refer to
page 11 for more information
about each of the features.
SELECT
SLAVE
MASTER
R
OPEN LEFT
OP
OPEN RIGHT
GHT
BRAKE OFF
R
BRAKE ON
N
OPEN
OPENING CLOSING CLOSED
CLOSE TIMER OFF
CLOSE TIMER ON
OPENING
CLOSING
LIMIT
LIMIT
OFF—ON
FEATURE SELECTOR
TIMER
ERD CONTROL
GATE STATUS
S1 S2
FCN
0
1
ON ON
STOP N/C
ON OFF CLOSE
M/S PHASE
RESET
OFF ON
PHANTOM
OFF OFF EDGE SENSOR
MULTI FUNCTION
ERD OVERLOAD
Slave Board
GND
#1
RCVR
24VAC
GND
#2
#3
#4
#5
#6
#7
#8
#9
SLAVE MASTER
+ –
+ –
INPUT/OUTPUT
COMM PORT
COMM PORT
POWER
17