Amantii 40-TRV-SLIM Installation And Operation Instructions Manual

Amantii 40-TRV-SLIM Installation And Operation Instructions Manual

Advertisement

Quick Links

INSTALLATION AND OPERATION INSTRUCTIONS FOR
30-TRV-SLIM
40-TRV-SLIM
50-TRV-SLIM
60-TRV-SLIM
72-TRV-SLIM
SAFETY INFORMATION
WARNING
If the information in these instructions are
not followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 40-TRV-SLIM and is the answer not in the manual?

Questions and answers

Summary of Contents for Amantii 40-TRV-SLIM

  • Page 1 INSTALLATION AND OPERATION INSTRUCTIONS FOR 30-TRV-SLIM 40-TRV-SLIM 50-TRV-SLIM 60-TRV-SLIM 72-TRV-SLIM SAFETY INFORMATION WARNING If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    Please read and carefully follow all instructions found in this manual. Please pay special attention to the safety instructions provided in this manual. The instructions included here will assure that you have many years of dependable and enjoyable service from your Amantii product. IMPORTANT INSTRUCTIONS ............................
  • Page 3: Important Instructions

    IMPORTANT INSTRUCTIONS PLEASE RETAIN THIS USER GUIDE FOR FUTURE REFERENCE When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1) Read all instructions before using this fireplace 2) The fireplace is hot when in use.
  • Page 4: Unpacking And Testing Appliance

    UNPACKING AND TESTING APPLIANCE Carefully remove the appliance from the box. Prior to installing the appliance, test to make sure the appliance operates properly by plugging the power supply cord into a conveniently located 120 Volt grounded outlet. Test all aspects of its operation (manual switches, remote and heater) to make sure all components operate correctly.
  • Page 5: 30-Trv-Slim

    30-TRV-SLIM This appliance has been tested in accordance with the UL Standard 2021 Description Built-in Appliance for fixed and location dedicated Voltage 120V AC 60Hz electric room appliances in the United Watts 1500W Max States and Canada. If you need NO HEATER assistance during installation, please MOTOR HEATER...
  • Page 6: 40-Trv-Slim

    40-TRV-SLIM This appliance has been tested in accordance with the UL Standard 2021 Description Built-in Appliance for fixed and location dedicated Voltage 120V AC 60Hz electric room appliances in the United Watts 1500W Max States and Canada. If you need...
  • Page 7: 50-Trv-Slim

    50-TRV-SLIM This appliance has been tested in accordance with the UL Standard 2021 Description Built-in Appliance for fixed and location dedicated Voltage 120V AC 60Hz electric room appliances in the United Watts 1500W Max States and Canada. If you need NO HEATER assistance during installation, please MOTOR HEATER...
  • Page 8: 60-Trv-Slim

    60-TRV-SLIM This appliance has been tested in accordance with the UL Standard 2021 Description Built-in Appliance for fixed and location dedicated Voltage 120V AC 60Hz electric room appliances in the United Watts 1500W Max States and Canada. If you need NO HEATER assistance during installation, please MOTOR HEATER...
  • Page 9: 72-Trv-Slim

    72-TRV-SLIM This appliance has been tested in accordance with the UL Standard 2021 Description Built-in Appliance for fixed and location dedicated Voltage 120V AC 60Hz electric room appliances in the United Watts 1500W Max States and Canada. If you need NO HEATER assistance during installation, please MOTOR HEATER...
  • Page 10: Safety Drill Screw Area

    SAFETY DRILL SCREW AREA There is a safety drill screw area as show below. Please make sure that the fix screws are in this area. T h e m a n u a l c o n tro l p a d p o s itio n Sa fe ty d rill s cre w a re a (Da rk a re a ) HARD- WIRE INSTALLATION...
  • Page 11: For Bathroom Use

    2. Attach the wiring to the junction block. Please make sure the live wire goes into the “L”, the neutral wire into “N” and the ground wire into “G”. 3. Put the plate back and screw back. FOR BATHROOM USE If this unit is installed in a bathroom it must be protected by a GIF receptacle or circuit.
  • Page 12: Outdoor Installations

    OUTDOOR INSTALLATION The TRV-SLIM series electric fireplaces are suitable for installation in outdoor areas protected from direct water impingement. In addition to maintaining the listed mantel and combustibles clearances, a rain protection overhang factor of 1/2 shall be constructed to the front and to each side of the installed appliance.
  • Page 13: Installation

    H(") 2. Take off the fending bars and panels if you 30-TRV-SLIM 33 3/4 11 1/8" 27 1/8 want to view the fire from three angles. 40-TRV-SLIM 43 3/4 11 1/8" 27 1/8 50-TRV-SLIM 53 3/4 11 1/8" 27 1/8...
  • Page 14 framing plate framing plate 5. Make an opening for the fireplace according to requested measurement. 7. After checking that the fireplace operates properly, cover the glass panels with protective plastic bag and install plywood or drywall. 6. Insert the fireplace into the wall opening. Drive the mounting screws into the frame plates on the unit and the wall studs.
  • Page 15 8. Decorate the plywood or drywall with glazed tile, wallpaper, etc. 3. After the fending panel is removed, screw back the bar. Installation for Front and right side Viewing 1. To install the fireplace where the left side is close to a wall, and you want to view the fire from front and right side, take off the fending panel on the right.
  • Page 16 5. Make an opening for the fireplace according 7. After checking that the fireplace operates to requested measurement. properly, cover the glass panels with protective plastic bag and install plywood or drywall. 6. Insert the fireplace into the wall opening. Drive the mounting screws into the frame plates on the unit and the wall studs.
  • Page 17 Installation for Front and Left Side Viewing 1. Install the fireplace where the right side is close to a wall, and you want to view the fire from front and left side, take off the fending panel on the left. 4.
  • Page 18 7. After checking that the fireplace operates properly, cover the glass panels with protective plastic bag and install plywood or drywall. 6. Insert the fireplace into the wall opening. Drive the mounting screws into the frame plates on the unit and the wall studs. To fix the bottom of the fireplace and the wall studs with the framing plates that you’ve removed from left and right side of the...
  • Page 19: Media Options

    MEDIA OPTIONS The TRV-SLIM series models are shipped with DESIGN-MEDIA-BIRCH-10PCE. DESIGN-MEDIA-BIRCH-10PCE MEDIA OPERATION 3. Take off the front glass panel and put it in safe place. 1. Unscrew 2 screws and take off two brackets which are fending the front glass panel. Screws and brackets 4.
  • Page 20: Operation

    OPERATION The fireplace can be operated either by the switches located on the left bottom of the fireplace unit or by supplied remote control. Plug the fireplace into a 15 Amp wall socket. MANUAL OPERATION 1. The main power ON/OFF switch in position O, the fireplace is OFF. 2.
  • Page 21 REMOTE CONTROL OPERATION For remote to function make sure the heater is plugged in and main power switch located on the bottom left hand side is at position I. When operating the remote make sure you point the remote to the centre of the fireplace and make sure each time you press the button.
  • Page 22: Installing Wall Thermostat

    INSTALLING WALL THERMOSTAT WALL THERMOSTAT WIRING DIAGRAMS Wire the wall thermostat prior to installing the fireplace. WALL THERMOSTAT WIRING(24 VAC) Install Wall Thermostat per instructions provided with kit and per the following information: 1. Turn off circuit breaker. 2. Remove cover plate located on the left side of appliance. Pull the wire out and cut the inside thermostat.
  • Page 23: Replacement Parts

    REPLACEMENT PARTS This list contains replacement parts PART NUMBER DESCRIPTION 30-TRV-SLIM 40-TRV-SLIM 50-TRV-SLIM 10701384 10701281 10701216 Front Clear Glass 10201505 ADJUSTABLE SCREW FRONT CLEAR GLASS 3123010 BRACKET 10702266 10702267 10702268 BOTTOM TRAY GLASS 10702271 10701284B 10701219B BACK GLASS 10701385 SIDE CLEAR GLASS...
  • Page 24 This list contains replacement parts PART NUMBER DESCRIPTION 60-TRV-SLIM 72-TRV-SLIM 10701217 10701218 Front Clear Glass 10201505 ADJUSTABLE SCREW FRONT CLEAR GLASS 3123010 BRACKET 10702269 10702270 BOTTOM TRAY GLASS 10701220B 10701221B BACK GLASS 10701385 SIDE CLEAR GLASS 601136B 601137B LED STRIP FOR TRAY AND FLAME 601141B 601141B...
  • Page 25: Exploded View

    EXPLODED VIEW...
  • Page 26: Wiring Diagram

    Wiring Diagram...
  • Page 27: Trouble Shooting

    TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Dim or no flame Flame LED’s are burnt out Inspect the LED’s and replace them if necessary. Ember Ember LED’s are burnt out Inspect the ember bed LED’s and glowing or dimming replace them if necessary. Appliance turns off and Appliance has overheated and Turn off the main switch, allow...
  • Page 28: Service History

    SERVICE HISTORY This heater must be serviced annually depending on usage. Date Dealer Service technician Service Performed Special Concerns Name Name NOTES:...

This manual is also suitable for:

30-trv-slim50-trv-slim60-trv-slim72-trv-slim

Table of Contents