1. Overview

1.1 Features

Item
Core CPU supported
Host interface
Program break functions
Target program running time measurement
function
Clock (DCLK) frequency for communicating
with the target MCU
Flash memory programming power supply
Target system reset signal output
Target system I/O interface voltage range
Target system interface connector
Power supply for target system
*1 Clock frequency that is output from the S1C17 MCU's DCLK pin during debug mode
*2 After power is turned on, the ICD mini Ver. 3.0 is configured so that the I/O interface voltage will be supplied
from the target system. It can be reconfigured from the host computer. For more information, refer to the
manual for the S1C17 Family C Compiler Package Ver. 3.0.0 or later.
*3 A target system connection cable with the target system side connectors compatible with the ICDmini Ver. 1.0,
1.1, and 2.0 is available as an option.

1.2 Operating Environment

The ICDmini Ver. 3.0 requires a PC equipped with a USB port as the host computer. For the operating systems
supported, refer to the manual for the S1C17 Family C Compiler Package Ver. 3.0.0 or later.
2
Table 1.1.1 Features of ICDmini Ver. 3.0
Feature
S1C17 Core
USB Ver. 2.0 (Full speed)
PC break and forced break functions
Available
Max. 24 MHz *1
Available (Either 7.0 V or 7.5 V output voltage can be selected
from the host computer.)
Available
1.2 V to 5.5 V (input from the target system) or 3.3 V fixed *2
2.54 mm-pitch 10-pin connector *3
Available (3.3 V, max. 100 mA)
Seiko Epson Corporation