Target System Interface Connector - Epson ICDmini 3.0 User Manual

Cmos 16-bit single chip microcontroller
Table of Contents

Advertisement

4.1.1 Target System Interface Connector

This connector is used for the purposes listed below.
• To communicate with the target S1C17 MCU
• To output a reset signal to the target system
• To supply the programming power voltage for the flash memory embedded in the target S1C17 MCU
• To input the target system interface voltage
Use the target system connection cable supplied with the ICDmini Ver. 3.0 to connect the target system. Table
4.1.1.1 lists the target system interface connector pin assignment.
Figure 4.1.1.1 Target System Interface Connector on the ICDmini Ver. 3.0 Left Side Panel
Table 4.1.1.1 Target System Interface Connector Pin Assignment Table
Target System Interface Connector (10 pins)
No
Pin name
1
DCLK
2
GND
3
DSIO
4
DST2
5
FLASH_VCC_OUT
6
GND
7
TARGET_RST_OUT
8
TARGET_VCC_IN
9
VCC3.3V
10
N.C.
ICDmini Ver. 3.0 User Manual
(Rev. 1.0)
Pin 1
I/O
Pin function
I
Clock signal input for debugging
Ground
I/O
Serial communication signal input/output for debugging
I
Debug status signal input
Flash memory programming voltage output
Ground
O
Target system reset signal output
Target system power supply voltage input
Power supply (3.3 V)
Unused
Seiko Epson Corporation