Set Port Alarm Limits Screen - Cabletron Systems IRM/LM User Manual

Local network management for cabletron systems
Table of Contents

Advertisement

SETTING ALARM LIMITS
7.3

SET PORT ALARM LIMITS SCREEN

Port Alarm Limits allow you to set an alarm limit for each port on a board.
These alarm limits can be configured to advise you that a certain number
of good packets or collisions have passed through the port within a given
time period, within a specified count of good packets or collisions
processed by the MMAC, or by a specified count of good packets or
collisions processed by a board. For example, a Port Alarm Limit can be
set to advise you when more than 1,000 good packets have passed through
the port in 10 seconds. This limit can be set to disable the port when the
limit is reached.
Port Alarm Limits are set at the Set Port Alarm Limits Screen. To access
this screen:
1. Highlight the PORT LIMITS - BOARD X option at the bottom of the
Board Limits Screen.
2. Press Return. The Set Port Alarm Limits Screen, Figure 7-3, will
appear.
02/16/90
14:32:01
MMAC Name: TECH WRITING
Packets/
Colls.
MMAC Limit:
1000
Board 0 Limit:
1000
Port
Packets/Colls.
1
100
2
100
3
100
4
100
MAIN
SAVE
7-6
Set Port Alarm Limits
-C 00:00:10 DISABLED!
-C 00:00:10 DISABLED!
-C 00:00:10 DISABLED!
-C 00:00:10 DISABLED!
-C 00:00:10 DISABLED!
-C 00:00:10 DISABLED!
BOARD LIMITS SCREEN
Figure 7-3 Set Port Alarm Limits Screen
Last Reset: 02/16/90 14:29:40
Board 0 Name: TECH WRITING
Within
Within
Auto
Shut-off
NO
NO
Auto Shut-off
Status
NO
NO
NO
NO
SYSTEM PARAMETER SCREEN
Parts
ON
OFF
16
0
4
0
SEG
SEG
SEG
ON

Advertisement

Table of Contents
loading