• The transceiver to which the MR-2000C will be connected to must meet IEEE 802.3 standards and not
have the SQE test function enabled.
• The AUI cable connecting the MR-2000C to the transceiver on the network must be IEEE 802.3 type
cable and must not exceed 50 meters in length.
• From its source address to its destination address, a data packet may pass through four repeaters.
2.3 SITE SELECTION GUIDELINES. The following guidelines must be followed to select a site for
the MR-2000C Multiport Repeater. If not, unsatisfactory network performance may result.
• An unrestricted free surface area of 21 inches wide, 18 inches deep and 6 inches high is needed.
• A USA standard 3 prong power receptacle must be located within 7 feet of the site.
• If a shelving unit is to be used, it must be able to support 30 pounds of static weight.
• The temperature of the location must be maintained between 5 and 40 C. Temperature changes greater
than 10 C per hour must not occur.
2.4 SET-UP FOR OPERATION. Set-up the MR-2000C Multiport Repeater for operation as follows:
1. Unpack the MR-2000C as follows:
a. Remove the repeater from shipping box.
b. Slide the two foam end caps off the repeater.
c. Remove the repeater from protective plastic bag and set the repeater aside in a safe place.
d. Remove the plastic bag containing the accessory package and check that all items listed below are
in the bag:
One 8 foot USA power cord.
One cable support bracket.
Two 8-32 x .375 in. screws.
Three 6 in. cable ties.
Save the shipping box and materials in the event the repeater has to
be reshipped.
2. Using the two 8-32 screws (3, Fig. 2-1), attach the cable support (2) to the repeater (1).
3. Place the repeater on the selected site.
Be sure that the site meets the guidelines listed in Section 2.3.
NOTE
CAUTION