Basket Lift Problems; Auto Top Off Problems - Welbilt FRYMASTER FilterQuick FQE30 Installation, Operation And Maintenance Manual

Hide thumbs Also See for FRYMASTER FilterQuick FQE30:
Table of Contents

Advertisement

Problem
filtration won't
start.
Controller display
shows filter
busy.

6.2.4 Basket Lift Problems

Problem
Basket lift movement is
jerky and/or noisy.
6.2.5 Auto Top-Off Problems
Problem
Frypots won't top off.
One vat doesn't top
off.
Controller displays
TOPOFF OIL
EMPTY /
CONFIRM
Probable Causes
B. Check that MIB board is not
in manual mode.
C. Check to see that the MIB
cover is not damaged and
depressing the buttons.
D. Filter relay has failed.
Another filtration cycle or filter
paper change is still in process.
Probable Causes
Basket lift rods need lubrication.
Probable Causes
A. Crumb build up around sensor.
B. Fryer temperature too low.
C. Oil is too cold.
D. JIB out of oil
E. A fryer may be unplugged or fryer
with ATO box may not have power.
F. Service required error exists
A. Filter error exists.
B. Service required error exists
C. Solenoid, pump, pin issue, RTD or
ATO issue.
Top off system out of oil.
Corrective Action
sensor.
B. Ensure MIB board is in "A" automatic
mode. Power cycle the fryer.
C. Remove and replace cover and see if
filtration will start.
D. Call your FAS for assistance.
Wait until the previous filtration cycle ends to
start another filtration cycle. Change filter
paper if prompted.
Corrective Action
Apply a light coating of Lubriplate
lightweight white grease to the rod and bushings.
Corrective Action
A. Clean
surrounding sensor.
B. Fryer temperature must be at
setpoint.
C. Ensure that the oil in the JIB is
above 70°F (21°C).
D. Ensure the JIB is not out of oil and
supply line is in the JIB. Replace
JIB and press the  button when
prompted and press and hold the
ORANGE reset button for ten (10)
seconds to reset top off system.
If problem persists call your FAS
for assistance.
E. Check plugs, breakers and
switches.
F. Call your FAS for assistance.
A. Clear filter error properly. If
problem persists call your FAS for
assistance.
B. Call your FAS for assistance.
C. Call your FAS for assistance.
Fill top off system with oil and press
the  (CONFIRM) button. Once the
JIB is replaced press and hold the
orange reset button for ten (10)
seconds to reset top off system.
6-5
or similar
crumbs
from
opening

Advertisement

Table of Contents
loading

Table of Contents