The controller displays REMOVE PAN.
*NOTE: If the filter paper change time has expired, normally every 25
hours, the CHANGE FILTER PAPER? message repeats every 15
minutes instead of every four minutes.
6. Remove the pan. The controller display changes to CHANGE PAPER. Change the filter
paper and ensure the filter pan has been pulled forward, out of the cabinet for at least 30 seconds.
Once the pan has been out for 30 seconds the controller displays OFF. Ensure the pan is dry
and assembled correctly. Push the filter pan back into the fryer. Ensure "A" is displayed on the
MIB board.
7.
Switch the controller on. The controller displays the fryer temperature until the fryer reaches
setpoint.
8. If a filtration error occurs six consecutive times, the return valve closes and the controller
displays SERVICE REQUIRED alternating with YES and an alarm.
9. Press 
(YES)
to silence alarm and continue.
The controller displays SYSTEM ERROR and the error message for 15
seconds changing to SYSTEM ERROR FIXED alternating with YES
NO.
10. Press 
(NO)
to continue cooking. Call your FAS to repair and reset
the fryer. The error will be re-displayed every 15 minutes until the issue
is repaired. Semi-automatic filtration and auto top off is disabled until
the fryer is reset.

4.5 Filter Busy

When FILTER BUSY is displayed on the controller, the system is waiting on another vat to be
filtered or waiting on another issue to clear. Wait 15 minutes to see if problem is corrected. If not,
call your local FAS.
Do not drain more than one frypot at a time into the built-in filtration unit to avoid
overflow and spillage of hot oil that may cause severe burns, slipping and falling.
The filter pump is equipped with a manual reset switch in case the filter motor
overheats or an electrical fault occurs. If this switch trips, turn off power to the filter
system and allow the pump motor to cool 20 minutes before attempting to reset the
switch (see photo on the next page).
Use caution and wear appropriate safety equipment when resetting the filter pump
reset switch. Resetting the switch must be accomplished with care to avoid the
possibility of a serious burn from careless maneuvering around the drain tube and
frypot.
DANGER
WARNING
WARNING