Troubleshooting (for service personnel)
The room does not cool down/warm up
Case
Air does not come out.
Air does not come out /
Air comes out.
Air comes out.
Air has an odour
Case
The air conditioner gives off an
odour.
Mist comes out
Case
Mist comes out of the indoor unit.
Remote controller
Case
The unit does not receive signals
from the remote controller or has a
low sensitivity.
LCD is faint, is not working, or
displays erratically.
Other electric devices start
operating.
2 air conditioners start operating at
the same time.
43 43
Description / where to check
„ In HEATING operation
• The air conditioner is warming up. Wait for about 1 to 4 minutes.
„ In COOLING / "SARARA" DRY / DRY COOLING operation
• When the airfl ow rate setting is "AUTO", a function to prevent emission of an odour
contained in the indoor unit operates. This keeps air from coming out immediately after
operation is started. Wait for about 40 seconds.
„ Is the airfl ow rate setting appropriate?
• Is the airfl ow rate setting low, such as "Indoor unit quiet" or "1"? Increase the airfl ow rate
setting.
„ Is the set temperature appropriate?
„ Is the adjustment of the airfl ow direction appropriate?
• Is there any furniture directly under or beside the indoor unit?
• Is the air conditioner in ECONO operation?
• Are the air fi lters dirty?
• Is there anything blocking the air inlet or air outlet of the indoor unit or outdoor unit?
• Is the window or door open?
• Is the exhaust fan turning?
Description / where to check
• When operation is switched to "SARARA" DRY operation, the humidity may increase
temporarily, which may generate an odour.
• The room odour absorbed in the unit is discharged with the airfl ow.
We recommend you to have the indoor unit cleaned. Consult the service shop.
• The air outlet may give out an odour because a small amount of ozone is generated.
However, the amount is very small and does not harm your health.
• This happens when the unit is in MOLD PROOF operation.
Description / where to check
• This happens when the air in the room is cooled into mist by the cold airfl ow during
COOLING or other operation.
• This is because the air in the room is cooled by the heat exchanger and becomes mist
during defrost operation.
Description / where to check
• The batteries may be exhausted.
Replace all the batteries with new dry batteries AA.LR6 (alkaline).
For details, refer to "Preparation before operation".
• If the remote controller activates other electric devices, move them away or consult the
service shop.
• If you do not want to operate 2 air conditioners at the same time, change the address
setting.
 Page 34
 Page 14
 Page 25
 Page 27
 Page 9