CONTENTS Before Operation Safety precautions ...................... 3 Names and functions of parts ..................5 Preparation before operation ..................9 To set the batteries To set the clock To set the position where the indoor unit is installed Basic Operation To set operation modes ..................... 11 AUTO COOLING “SARARA”...
English Before Operation To purify the air in the room ..................24 Basic Operation FLASH STREAMER AIR PURIFYING FRESH AIR SUPPLY VENTILATION To consider the environment of use ................25 Useful Functions ECONO OUTDOOR UNIT QUIET To keep the air conditioner clean ................27 Cleaning MOLD PROOF CLEANING FILTER To know the status of your room and air conditioner ..........
Safety precautions Read the precautions in this manual carefully This appliance is filled with R32. before operating the unit. • Keep this manual where the user can easily find it. • The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail.
• Do not place appliances that produce naked flames in places exposed to the airflow from the unit as this may impair combustion of the burner. • Do not block air inlets nor outlets. Impaired airflow may result in insufficient performance or trouble. •...
Names and functions of parts Indoor unit Air inlet INTELLIGENT EYE sensor (top surface) Front panel Auxiliary fl ap Louvres (vertical blades) (horizontal blade) (Inside of the air outlet located on the right and left sides.) Page 13 Page 13 Shutter Flap (horizontal blade) (bottom...
Page 7
When the front panel is open Page 35 Display unit Indoor unit ON/OFF switch • Press to start the operation with the mode set to INTELLIGENT EYE sensor “AUTO” and airfl ow rate to “AUTO”. Press the button again to stop the operation. Detects human motion to confi rm that a person is in •...
Page 8
Names and functions of parts Remote controller Transmitter/Receiver Transmitter/Receiver Display (LCD), with backlight • Displays the operating conditions. (All displayed here for your reference.) (All displayed here for your reference.) • Press any of the operation buttons to light Press any of the operation buttons to light the backlight for about 5 seconds.
Open the cover A menu item is shown above. A menu item is shown below. Airfl ow direction buttons FLASH STREAMER AIR PURIFYING Page 24 Adjust the vertical and horizontal airfl ow directions. Page 13 FRESH AIR SUPPLY VENTILATION ...
Preparation before operation To set the batteries Pull down the upper tab to open the cover. Insert 2 dry batteries AA.LR6 (alkaline). • Using batteries other than AA.LR6 (alkaline) may lead to Upper tab improper operation. Do not confuse Insert the 2 lower tabs on the cover to put sides.
To set the clock Press Press to set the clock to the current time. • Each time you press , the time changes by 1 minute. If you press and hold the button, the time changes by 10 minutes. Press •...
To set operation modes AUTO operation To operate in appropriate operation mode (COOLING or HEATING) based on the set temperature and the indoor temperature. Press COOLING operation To lower the temperature. Press “SARARA” DRY operation To lower the humidity. Press DRY COOLING operation To lower the temperature and humidity.
Page 13
To adjust the temperature Press To adjust the humidity Press Notes on humidity settings Setting Description Keeps the humidity high and does not blow air directly on the body to make the operation gentle to your : MOISTURISING skin. The operation is recommended when you are worried about the dryness of your skin. The airflow rate cannot be changed.
To adjust the airflow To adjust the airflow rate Press • Each time you press the button, the airflow rate indicator changes. (Some indicators may not appear depending on the operation mode. Page 14 ..AUTO Indoor unit quiet Airflow rate 1-5 •...
Notes on airflow rate • When the airflow rate setting is “AUTO”, starting COOLING, “SARARA” DRY, or DRY COOLING operation (including the operation selected with “AUTO”) triggers the deodorising function which reduces odour coming from the indoor unit and the unit does not blow air immediately.
Page 16
To adjust the airfl ow Note on 3-D airfl ow • Using 3-D airfl ow circulates cold air, which tends to collect at the bottom of the room, and hot air, which tends to collect near the ceiling, throughout the room, preventing areas of cold and hot developing. Note on horizontal airfl ow direction •...
To operate wisely using the sensor 3 Area INTELLIGENT EYE operation Whether to blow air away from a person or not can be set according to your preference. The INTELLIGENT EYE sensor detects the movement of a person and automatically changes the airflow direction.
To use the timer ON/OFF TIMER operation This function controls the operation start and stop time. When you set the timer, you can select the operation frequency either once or daily. < To use the operation > Press Press to select the item and press 24 HOUR ON TIMER 24 HOUR OFF TIMER C-SLEEP TIMER...
Page 19
COUNTDOWN OFF TIMER operation You can set the timer for the remaining time until the scheduled stop. The timer should be set each time. < To use the operation > Press • The time can be set in increments of 30 minutes each time the button is pressed (from 30 minutes to 9 hours 30 minutes).
To ensure a comfortable sleep COMFORT SLEEP TIMER operation COMFORT SLEEP TIMER operation keeps the indoor temperature and humidity at suitable levels for a comfortable sleep and refreshing morning. < To use the operation > Press during COOLING or HEATING operation. Press to select the item and press 24 HOUR ON TIMER...
Page 21
Notes on COMFORT SLEEP TIMER operation • When COMFORT SLEEP TIMER is set, the upper limit of the set temperature of HUMID HEATING is 22°C. • After the COMFORT SLEEP TIMER operation is fi nished, the operation displayed on the remote controller will continue. •...
To guarantee high heating capacity when you wake up QUICK HEATING TIMER operation This operation quickly blows warm air when the HEATING operation starts in the morning and makes a warm space (warmth zone) around the indoor unit. How to set the QUICK HEATING TIMER Press Press to select the item and press...
Page 23
< To change or cancel the setting > Follow steps 1 and 2 on page 21 and then select the timer setting you want to change. Press to select the item and press Setting change TIMER cancel • Settings can be cancelled with •...
To increase the cooling or heating power POWERFUL operation POWERFUL operation quickly maximises the cooling/heating effect. You can get the maximum capacity. < To use the operation > Press during COOLING or HEATING operation. • When POWERFUL operation is set, the operation mode will be changed as follows.
To purify the air in the room FLASH STREAMER AIR PURIFYING operation Flash streamer discharge decomposes mold and allergic substances to clean the air in the room. FRESH AIR SUPPLY VENTILATION operation The air in the room is cleaned, taking in fresh air from outside. <...
To consider the environment of use ECONO operation ECONO operation enables efficient operation by limiting the maximum power consumption value. This function is useful for ensuring a circuit breaker does not trip when the unit runs alongside other appliances. OUTDOOR UNIT QUIET operation OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency and fan speed on the outdoor unit.
Page 27
Notes on ECONO operation < Image of running current and power consumption in ECONO operation > Maximum during normal operation Normal operation Maximum during ECONO operation The maximum running current and power consumption of the air conditioner in ECONO operation vary with the ECONO connecting outdoor unit.
To keep the air conditioner clean MOLD PROOF operation The inside of the air conditioner is dried to reduce the occurrence of mold and odour. When COOLING, “SARARA” DRY, or DRY COOLING operation is performed, condensation may occur inside the air conditioner and may cause mold or odour. It is recommended to dry the inside of the air conditioner by MOLD PROOF operation.
CLEANING FILTER operation The air fi lter will automatically be cleaned. < To automatically operate: Default “On” > Press during operation. • “ ” is displayed on the LCD. • The air fi lter will automatically be cleaned according to the operating hours (about once per day).
Page 30
To keep the air conditioner clean Notes on MOLD PROOF operation • This operation dries the inside of the air conditioner with the FAN ONLY and HEATING operation. • This operation dries the inside of the air conditioner while streamer discharge is performed to reduce the development of mold and odour inside the air conditioner.
To know the status of your room and air conditioner INFORMATION The indicator displayed on the LCD gives information about temperature, power consumption, and so on. The indicated indoor and outdoor temperatures are measured near the indoor and outdoor units. The indicator should be used as a guide only.
To change the default settings Menu settings You can change the default settings according to your room’s environment and your taste. < To change the setting > 1/12 Press Press to select the item and press Menu items Page INTELLIG.EYE AIRFLOW AUTO OFF time BREEZE AIRFLOW HUMIDIFY AIRFLOW...
Menu Setting Description The INTELLIGENT EYE sensor detects an area where there is a person and adjusts the Focus horizontal airfl ow direction to blow air directly on the person. INTELLIG.EYE AIRFLOW The INTELLIGENT EYE sensor detects an area where there is a person and adjusts the Comfort * horizontal airfl ow direction to avoid blowing air directly on the person.
To change the default settings Menu Setting Description On * CONTINUE DRY operation is performed. CONTINUE CONTINUE DRY operation is not performed. < Note > • When the indoor temperature or humidity falls far below the preset value, the fans of indoor and outdoor units are stopped to keep the room comfortable.
Menu Setting Description • You can set the contrast between 1 and 5. The default setting is “3”. CONTRAST 1 to 5 • The higher the figure, the darker the indicator. < Note > • This function sets the contrast of the LCD. Push APPLY Starts 24 HOUR FRESH AIR SUPPLY VENTILATION operation.
Cleaning (for service personnel) CAUTION • Be sure to stop the operation and turn off the circuit breaker before cleaning. • For care and cleaning, call service personnel. Streamer unit INTELLIGENT EYE sensor Page 36 Front panel Dust box / Dust brush Air supply fi lter (black) ...
CAUTION • Do not touch the aluminium fi ns of the indoor unit. (It may cause an injury.) • Do not use the following to clean the air conditioner. (It may cause deformation, discolouration or scratches.) – Water hotter than 40°C –...
Cleaning (for service personnel) Dust box / Dust brush When? < Removing or attaching the dust brush > 1) Pull the centre of the dust brush. When the MOLD PROOF / CLEANING FILTER lamp (green) 2) Take out the dust brush from the right-side and left-side shaft blinks.
Page 39
When you clean the fi lters, open the front panel and remove the dust box. Air fi lter (white) If the AUTO CLEANING FILTER operation is set to “On”, basically Attaching the air fi lter no care is required. Page 28 When you are aware of dirt, such as when oil or nicotine is Hold the grips (blue) and insert the attached to the air fi lter or when the AUTO CLEANING FILTER...
Page 40
Cleaning (for service personnel) When you clean the fi lters, open the front panel and remove the dust box. • Dispose of old fi lters as non-fl ammable waste. Photocatalytic air-purifying and • To order a photocatalytic air-purifying and deodorising fi lter, deodorising fi lter (black) contact the service shop where you bought the air conditioner.
When the OPERATION lamp (green) blinks When the OPERATION lamp (green) blinks, turn off the circuit breaker. After about 1 minute, turn it on again and start operation. If the OPERATION lamp still blinks, check the error code according to the steps below and OPERATION lamp (green) take appropriate action.
Indoor unit Commonly occurring sounds A hissing sound • This is a sound generated when humidified air or ventilated air is discharged. • Operating sound may vary depending on the outdoor temperature or humidity. Roaring sound • This is a sound of ventilating operation. (When ventilating operation is combined with COOLING/HEATING operation, it is possible to stop only ventilating operation.) ...
Troubleshooting (for service personnel) Before making an inquiry or a request for repair, check the following. If the problem persists, consult the service shop. Not trouble Check These cases are not troubles. Please check again before calling a repair person. The air conditioner does not operate Case Description / where to check...
Page 44
Troubleshooting (for service personnel) The room does not cool down/warm up Case Description / where to check Air does not come out. In HEATING operation • The air conditioner is warming up. Wait for about 1 to 4 minutes. ...
Remote controller Case Description / where to check The unit does not receive signals • The batteries may be exhausted. from the remote controller or has a Replace all the batteries with new dry batteries AA.LR6 (alkaline). low sensitivity. For details, refer to “Preparation before operation”. ...
Page 46
Troubleshooting (for service personnel) CLEANING FILTER operation Case Description / where to check CLEANING FILTER operation does • To protect the air fi lters, CLEANING FILTER operation is not performed when the indoor not function. temperature is 10°C or lower. ...
Call the service shop immediately WARNING When an abnormality (such as a burning smell) occurs, stop operation and turn the circuit breaker off. • Continued operation in an abnormal condition may result in troubles, electric shocks or fire. • Consult the service shop where you bought the air conditioner. ...
Page 48
Two-dimensional bar code is a code for manufacturing. 3P338603-1C M12B405B (1310) HT...
Need help?
Do you have a question about the FTXZ25NV1B and is the answer not in the manual?
Questions and answers