Hide thumbs Also See for FTXL20G2V1B:

Advertisement

FTXL-G - RXL-G
Daikin's unique position as a manufacturer of air
ISO14001 assures an effective environmental
conditioning equipment, compressors and
management system in order to help protect
refrigerants has led to its close involvement in
human•health•and the environment from the potential
environmental issues. For several years Daikin has
impact of our activities, products and services and to
had the intension to become a leader in the
assist in maintaining and improving the quality of
provision of products that have limited impact on
the•environment.
the environment. This challenge demands the eco
design and development of a wide range of
products and an energy management system,
resulting in energy conservation and a reduction of
waste.
Daikin Europe N.V. is approved by LRQA for its Quality
Management System in accordance with the ISO9001
standard. ISO9001 pertains to quality assurance regarding
design, development, manufacturing as well as to services
related to the product.
Daikin units comply with the European
regulations that guarantee the safety of
the product.
Daikin Europe N.V. is participating in the EUROVENT
Certification Programme. Products are as listed in the
EUROVENT Directory of Certified Products.
Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Oostende, Belgium
Specifications are subject to change without prior
www.daikin.eu
notice
BTW: BE 0412 120 336
RPR Oostende
The present publication is drawn up by way of information only
and does not constitute an offer binding upon Daikin Europe
N.V.. Daikin Europe N.V. has compiled the content of this
publication to the best of its knowledge. No express or implied
warranty is given for the completeness, accuracy, reliability or
fitness for particular purpose of its content and the products
and services presented therein. Specifications are subject to
change without prior notice. Daikin Europe N.V. explicitly
rejects any liability for any direct or indirect damage, In the
broadest sense, arising from or related to the use and/or
interpretation of this publication. All content is copyrighted by
Daikin Europe N.V..
EEDEN0 9 - 0 0 3

technical data

FTXL-G
RXL-G
EEDEN09-003

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FTXL20G2V1B

  • Page 1: Technical Data

    The present publication is drawn up by way of information only conditioning equipment, compressors and management system in order to help protect and does not constitute an offer binding upon Daikin Europe refrigerants has led to its close involvement in human•health•and the environment from the potential N.V..
  • Page 2 EEDEN09-003 technical data FTXL-G RXL-G...
  • Page 4: I Indoor Units

    • Split - Sky Air Indoor units pages 7 - 16 PAGE WALL FTX - R-410A heat pump MOUNTED UNIT Outdoor units pages 17 - 36 PAGE HEAT PUMP RXL-G R-410A PAIR APPLICATION Inverter controlled • Split - Sky Air...
  • Page 6: Table Of Contents

    • Indoor Units • R-410A • FTXL-G2V1B TABLE OF CONTENTS FTXL-G2V1B Features ............. 8 Specifications .
  • Page 7: Features

    • Indoor Units • R-410A • FTXL-G2V1B Features S p F T • Energy efficient: full range A class energy labels (COP = 4.58/EER = • Comfort mode reassures draught free operation 4.55) • 3D air flow • High heating capacity: up to 6.6 kW •...
  • Page 8: Specifications

    • Indoor Units • R-410A • FTXL-G2V1B Specifications 2-1 FOR INDOOR UNITS ONLY FTXL20G2V1B FTXL25G2V1B FTXL35G2V1B Nominal input Cooling 0.026 0.024 0.026 (Indoor only) Heating 0.028 0.030 0.032 2-2 TECHNICAL SPECIFICATIONS FTXL20G2V1B FTXL25G2V1B FTXL35G2V1B Casing Colour White Dimensions Packing Height...
  • Page 9: Electrical Specifications

    • Indoor Units • R-410A • FTXL-G2V1B Specifications 2-2 TECHNICAL SPECIFICATIONS FTXL20G2V1B FTXL25G2V1B FTXL35G2V1B Cooling Sound Power High Sound High Pressure Medium Silent Operation Heating Sound Power High Sound High Pressure Medium Silent Operation Refrigerant Type R-410A Piping Liquid (OD) Diameter 6.35...
  • Page 10: Dimensional Drawing & Centre Of Gravity

    • Indoor Units • R-410A • FTXL-G2V1B Dimensional drawing & centre of gravity 3 - 1 Dimensional drawing FTXL20-25G The mark (→) shows piping direction Air flow (Indoor) Rear Including Right Left mounting plate 50 Min 50 Min Space for Space for REQUIRED SPACE maintenance...
  • Page 11: Centre Of Gravity

    • Indoor Units • R-410A • FTXL-G2V1B Dimensional drawing & centre of gravity 3 - 2 Centre of gravity FTXL20-35G 4D059112A • Split Sky Air • Indoor Units...
  • Page 12: Piping Diagram

    • Indoor Units • R-410A • FTXL-G2V1B Piping diagram FTXL20-25G AINDOOR UNIT 6.4CuT Heat exchanger Thermistor on Cross flow fan heat exch. Field piping 6.4CuT Fan motor Field piping 9.5CuT 9.5CuT Refrigerant flow Cooling Heating 4D058897A FTXL35G INDOOR UNIT 6.4CuT Heat exchanger Thermistor on heat exch.
  • Page 13: Wiring Diagram

    • Indoor Units • R-410A • FTXL-G2V1B Wiring diagram 5 - 1 Wiring diagram FTXL20-35G WIRING DIAGRAM FIELD WIRING RECTIFIER OUTDOOR CAUTION Note that operation will restart automatically if TRANSMISSION the main power supply is turned off and than CIRCUIT back on again.
  • Page 14: Sound Data

    • Indoor Units • R-410A • FTXL-G2V1B Sound data 6 - 1 Sound pressure spectrum FTXL20G FTXL20G COOLING HEATING Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency (Hz) Octave band center frequency (Hz) 3D059557A 3D059557A NOTES...
  • Page 15 • Indoor Units • R-410A • FTXL-G2V1B Sound data 6 - 1 Sound pressure spectrum FTXL35G FTXL35G COOLING HEATING Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency (Hz) Octave band center frequency (Hz) 3D059559A 3D059559A NOTES...
  • Page 16 • Outdoor Units • R-410A • RXL-G2V1B TABLE OF CONTENTS RXL-G2V1B Features ............18 Specifications .
  • Page 17: Features

    • Energy efficient: full range A class energy labels (COP = 4.58/EER = • Daikin outdoor units are neat and sturdy and can be mounted easily 4.55) on a roof or terrace or simply placed against an outside wall. •...
  • Page 18: Specifications

    • Outdoor Units • R-410A • RXL-G2V1B Specifications 2-1 NOMINAL CAPACITY AND NOMINAL INPUT RXL20G2V1B RXL25G2V1B RXL35G2V1B For combination Indoor Units FTXL20G2V1B FTXL25G2V1B FTXL35G2V1B indoor units + outdoor units Cooling capacity Minimum Btu/h 4,800 5,800 5,800 Kcal/h 1,200 1,460 1,460...
  • Page 19 • Outdoor Units • R-410A • RXL-G2V1B Specifications 2-2 TECHNICAL SPECIFICATIONS RXL20G2V1B RXL25G2V1B RXL35G2V1B Type Propeller Air Flow Rate Cooling (Low) m³/min 31.4 30.6 48.9 Cooling (High) m³/min 36.0 37.3 50.9 Heating (Low) m³/min 22.6 27.2 43.1 Heating (High) m³/min 30.2 31.3 45.0...
  • Page 20: Electrical Specifications

    • Outdoor Units • R-410A • RXL-G2V1B Specifications 2-3 ELECTRICAL SPECIFICATIONS RXL20G2V1B RXL25G2V1B RXL35G2V1B Power Supply Name Phase Frequency Voltage 220-230-240 Current Nominal running Cooling (A) 2.38-2.28-2.19 2.99-2.89-2.80 3.98-3.78-3.59 current (RLA) Heating (A) 2.97-2.87-2.78 4.16-3.96-3.77 4.15-3.96-3.76 Starting current (cooling/heating) Wiring connections For Power Supply Quantity For connection with...
  • Page 21: Electrical Data

    Electrical data RXL20G Representative unit combination Power supply Comp. Indoor unit Outdoor unit Hz-volts Voltage range 50 - 220 Max. 50Hz 264V FTXL20G2V1B RXL20G2V1B 50 - 230 9.75 0.23 0.15 Min. 50Hz 198V 50 - 240 3D055009C SYMBOLS NOTES : Min. Circuit Amps (A) 1.
  • Page 22 • Outdoor Units • R-410A • RXL-G2V1B Electrical data RXL35G Representative unit combination Power supply Comp. Indoor unit Outdoor unit Hz-volts Voltage range 50 - 220 Max. 50Hz 264V FTXL35G2V1B RXL35G2V1B 50 - 230 19.75 0.27 0.15 Min. 50Hz 198V 50 - 240 3D059718A SYMBOLS...
  • Page 23: Capacity Tables

    • Outdoor Units • R-410A • RXL-G2V1B Capacity tables 4 - 1 Cooling capacity tables FTXL20G2V1B+RXL20G2V1B 10.4 Cooling 50Hz 220-240V 0.21 I n door Outdoor temperature (°CDB) (°C) (°C) Heating 50Hz 220-240V 10.6 I n door Outdoor temperature (°CWB) (°C)
  • Page 24 • Outdoor Units • R-410A • RXL-G2V1B Capacity tables 4 - 1 Cooling capacity tables FTXL25G2V1B+RXL25G2V1B 0.14 Cooling 50Hz 220-240V I n door Outdoor temperature (°CDB) (°C) (°C) Heating 50Hz 220-240V 11.2 I n door Outdoor temperature (°CWB) (°C) 3D062718 SYMBOLS NOTES 1.
  • Page 25 • Outdoor Units • R-410A • RXL-G2V1B Capacity tables 4 - 1 Cooling capacity tables FTXL35G2V1B+RXL35G2V1B 10.2 Cooling 50Hz 220-240V 0.18 I n door Outdoor temperature (°CDB) (°C) (°C) Heating 50Hz 220-240V 11.0 I n door Outdoor temperature (°CWB) (°C) 3D062719 SYMBOLS NOTES...
  • Page 26: Dimensional Drawing & Centre Of Gravity

    • Outdoor Units • R-410A • RXL-G2V1B Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing unit (mm) RXL20-25G Wall height on air outlet side = 4 x holes for anchor bolts Minimum space for air passage Drain outlet less than 1200 (M8 or M10) (I.D.
  • Page 27: Centre Of Gravity

    • Outdoor Units • R-410A • RXL-G2V1B Dimensional drawing & centre of gravity 5 - 2 Centre of gravity RXL20G 4D056351G RXL25G 4D059009B • Split Sky Air • Outdoor Units...
  • Page 28 • Outdoor Units • R-410A • RXL-G2V1B Dimensional drawing & centre of gravity 5 - 2 Centre of gravity RXL35G The position of foundation bolt 4D051638K • Split Sky Air • Outdoor Units...
  • Page 29: Piping Diagram

    • Outdoor Units • R-410A • RXL-G2V1B Piping diagram RXL20G Outdoor Unit Outdoor Air Temperate Thermistor Heat exchanger Heat exchanger Thermistor Motor Operated Valve (4.8 CuT) (6.4 CuT) (6.4 CuT) (4.8 CuT) Muffler Muffler With With Filter Filter Propeller Fan 9.5 CuT Muffler With...
  • Page 30 • Outdoor Units • R-410A • RXL-G2V1B Piping diagram RXL35G Outdoor unit Heat exchanger Outdoor temperature thermistor Capillary tube 1 Muffler with Refrigerant flow filter Capillary tube 2 Cooling Capillary tube 3 Heating Heat exchanger thermistor Capillary tube 4 Propeller fan Motor operated valve Accumulator Filter...
  • Page 31: Wiring Diagram

    • Outdoor Units • R-410A • RXL-G2V1B Wiring diagram 7 - 1 Wiring diagram RXL20G Field wiring Indoor Drain pan Outdoor Heater NOTE 1. Refer to the nameplate for the power requirements. 1. size: length 105 x width 185 2. Refer to purchasing specification AS303002, unless otherwise specified.
  • Page 32 • Outdoor Units • R-410A • RXL-G2V1B Wiring diagram 7 - 1 Wiring diagram RXL35G Power supply To indoor unit Drain pan Heater Sheet metal Indoor Field wiring NOTE 1. Refer to purchasing specification (discharge) (outdoor) AS303002, unless otherwise (Condenser) In case of heat specified.
  • Page 33: Sound Data

    • Outdoor Units • R-410A • RXL-G2V1B Sound data 8 - 1 Sound pressure spectrum RXL20G RXL20G COOLING HEATING Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency (Hz) Octave band center frequency (Hz) 3D059593A 3D059593A NOTES...
  • Page 34 • Outdoor Units • R-410A • RXL-G2V1B Sound data 8 - 1 Sound pressure spectrum RXL35G RXL35G COOLING HEATING Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency (Hz) Octave band center frequency (Hz) 3D059740A 3D059740A NOTES...
  • Page 35: Operation Range

    • Outdoor Units • R-410A • RXL-G2V1B Operation range RXL20-35G Cooling Heating Indoor temp. (°CWB) Indoor temp. (°CDB) Notes: The graphs are based on the following conditions: + Equivalent piping length + Level difference + Air flow rate high 3D062728 •...

This manual is also suitable for:

Ftxl25g2v1bFtxl35g2v1bRxl20g2v1bRxl25g2v1bRxl35g2v1b