5.
To enable the closed-loop function, press in the button on the panel
of the VH-STACK2 Stacking Module that is installed in the unit with
the master management agent. Use the tip of a pen or other pointed
object to achieve this..
In this stacking configuration, the first switch with the Management
Module has stack ID number 1 and the stack IDs increase consecutively
(up to 7) as switches are added to the stack.
Note the following points about closed-loop stack operation:
•
A VH-STACK2 Stacking Module must be installed with the master
Management Module in Unit 1.
•
If backup management is used in conjunction with the closed-loop
feature, the backup Management Module must be installed in Unit 2.
•
Any changes to the stack, including powering down of a unit or the
insertion of a unit, causes the stack to reboot.
•
The stack will re-number itself if a unit in the closed-loop stack fails.
Stacking Module and Interconnect Cables
Table 2-1 provides information for the Stacking Modules and interconnect
cables available for the VH-2402S2.
Table 2-1. Stacking Modules and Interconnect Cables
Part Number
VH-STACK2
VH-2402S-CBL
24 Installation
NOTE: Do not leave one end of a stacking cable
unconnected. Be sure both ends are properly
connected, or remove the cable entirely.
Functions
Description
Stack inter-
Stacking Module used to connect switches in a
connection
stack.
Unit ships with one 32 cm stack interconnect cable.
Stack inter-
Long (70 cm) stack interconnect cable for closed-
connection
loop stack connection.
VH-2402S2