Power And Connector Specifications - Enterasys RoamAbout AP-2000 Hardware Installation Manual

Enterasys roamabout ap-2000: install guide
Hide thumbs Also See for RoamAbout AP-2000:
Table of Contents

Advertisement

Power and Connector Specifications

Power and Connector Specifications
Access Point power and connector specifications are listed in the table below. These
specifications are provided for customers who want to provide their own site operating
power for the AP.
If the remote power feature is used, Enterasys strongly recommends that you test the cable
from the remote power injector to the AP for continuity and correct pinout (straight-through
cable) before power is applied. Enterasys assumes no responsibility if the specifications set
forth below are not followed.
Specification
Power
Consumption
Voltage Input
Regulation
Redundant Power
Application
Power Connector
2-8 Cabling and Wiring
Rating
5 Watts with 9 to 60 Volts DC
7 Watts with 10 Volts AC to 30 Volts AC
9 to 60 Volts DC
555 mA @ 9 Volts DC to 83 mA @ 60 Volts DC
Polarity Independent
or
10 Volts AC to 30 Volts AC
500 mA @ 10 Volts AC to 167 mA @ 30 Volts AC
Regulated or non-regulated UL Listed Class 2 power supplies may be
used.
Non-regulated power supply outputs should not exceed the stated
maximum voltages and should not fall below the stated minimum
voltages.
Redundant power may be applied to the AP.
Both power connections (front panel and Ethernet) are electrically
isolated.
Redundant power sources do not need to be matched for voltage or
polarity.
AC and DC sources may be used at the same time.
Coaxial Type Power Plug that mates with Switchcraft RAPC712 Jack
(Switchcraft 760 or equivalent).
Dimensions:
Inside Diameter: 2.5 mm (0.100 inches)
Outside Diameter: 5.5 mm (0.218 inches)
Barrel Length: 9.5 mm (0.375 inches)

Advertisement

Table of Contents
loading

Table of Contents